On Sun, 14 Dec 2014 01:54:26 -0600, Paul Edwards <mutazi...@gmail.com> wrote:

>I don't have z/OS so I can't do this myself.
>
>Would someone who has z/OS be able to raise an
>issue either directly with IBM or via SHARE?
>
>The problem is that IBM's ftp has a great option
>to preserve RDW when transferring a binary VB
>file from mainframe to PC, but it doesn't have
>an option to reverse that process.
>
>You can see the use of the "rdw" option below.

Are you sure that the rdw option doesn't work when sending from the PC to z/OS? 
I don't see anything in the documentation to indicate that the receiving z/OS 
would ignore it. 

Have you tried, from the PC:
  binary
  quote site rdw
  put ...

I would expect that to work, assuming that the records you're sending still 
have the RDWs on them.

-- 
Walt

----------------------------------------------------------------------