> The remaining problem is that I am not getting any diagnostic 
information,
> in other words, exactly *which* new failed -- which will of course make 
any
> bug of this sort in the field hard to find. I call CEEDUMP to get a call
> trace and it produces an *empty* four-line dataset. On the console I get
> 
> IEW4000I FETCH FOR MODULE CEEMENU3 FROM DDNAME *VLF*    FAILED BECAUSE
> INSUFFICIENT STORAGE WAS AVAILABLE.
> CSV031I LIBRARY ACCESS FAILED FOR MODULE CEEMENU3, RETURN CODE 24, 
REASON
> CODE 26080021, DDNAME *LNKLST*

  I would suggest putting the CEEDUMP-related modules in LPA.  Our 
intention in z/OS is that modules involved in the production of 
SYSABEND/SYSUDUMP/SYSMDUMP/IEATDUMP/SDUMP 
should be in LPA, so that they don't need get loaded into exhausted
REGION-constrained storage while trying to take a dump of 
REGION-constrained storage exhaustion.  (And I say "our intention"
because we do sometimes find cases where we did not do what we 
intended). 

Jim Mulder z/OS Diagnosis, Design, Development, Test  IBM Corp. 