W dniu 2017-02-06 o 14:59, Ron Burr pisze:
As far as I know, reading a physical sequential (or partitioned dataset member) 
in reverse order can only be done using BSAM (via the BSP macro). Not that many 
applications require that mode of processing. But if one does, well then, that 
appears to be the only option. Mind you, there are some restrictions inherent 
in using BSP, as the manual explains.
The COBOL manual states that you can process a QSAM tape dataset in reverse 
order by doing an OPEN REVERSED, but I suspect that the dataset will actually 
be processed using BSAM, not QSAM.

It's worth to mention that performance of reverse processing dataset on real tape is worse than horrible. And IMHO it's not argument for using virtual tapes but for not using datasets on tape for applications. Tapes are for backup and ML2.

--
Radoslaw Skorupka
Lodz, Poland






--
Treść tej wiadomości może zawierać informacje prawnie chronione Banku 
przeznaczone wyłącznie do użytku służbowego adresata. Odbiorcą może być jedynie 
jej adresat z wyłączeniem dostępu osób trzecich. Jeżeli nie jesteś adresatem 
niniejszej wiadomości lub pracownikiem upoważnionym do jej przekazania 
adresatowi, informujemy, że jej rozpowszechnianie, kopiowanie, rozprowadzanie 
lub inne działanie o podobnym charakterze jest prawnie zabronione i może być 
karalne. Jeżeli otrzymałeś tę wiadomość omyłkowo, prosimy niezwłocznie 
zawiadomić nadawcę wysyłając odpowiedź oraz trwale usunąć tę wiadomość 
włączając w to wszelkie jej kopie wydrukowane lub zapisane na dysku.

This e-mail may contain legally privileged information of the Bank and is 
intended solely for business use of the addressee. This e-mail may only be 
received by the addressee and may not be disclosed to any third parties. If you 
are not the intended addressee of this e-mail or the employee authorized to 
forward it to the addressee, be advised that any dissemination, copying, 
distribution or any other similar activity is legally prohibited and may be 
punishable. If you received this e-mail by mistake please advise the sender 
immediately by using the reply facility in your e-mail software and delete 
permanently this e-mail including any copies of it either printed or saved to 
hard drive.

mBank S.A. z siedzibą w Warszawie, ul. Senatorska 18, 00-950 Warszawa, 
www.mBank.pl, e-mail: kont...@mbank.pl
Sąd Rejonowy dla m. st. Warszawy XII Wydział Gospodarczy Krajowego Rejestru 
Sądowego, nr rejestru przedsiębiorców KRS 0000025237, NIP: 526-021-50-88. 
Według stanu na dzień 01.01.2016 r. kapitał zakładowy mBanku S.A. (w całości 
wpłacony) wynosi 168.955.696 złotych.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to