Sysmods can be (usually are) deleted from SMPPTS during ACCEPT. That's an update.
. . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW robin...@sce.com -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of CM Poncelet Sent: Friday, March 17, 2017 3:29 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: (External):Re: Can SMPPTS datasets be consolidated? Yes indeed. Anything can be done in SMP/E via UCLIN - e.g. "DEL GZONE ZONEINDEX(<whatever>)" + "ADD GZONE ZONEINDEX (<whatever>)" and then "SET BOUNDARY(GLOBAL)" + "UCLIN" + "REP DDDEF(SMPPTS) DA(<whatever else>) SHR" ... and so forth. What matters is to use native SMP/E in batch instead of IBM's "SMP/E for Dummies" dialogs. BTW SMPPTS is written to only during RECEIVE. Else it is only read. On 17/03/2017 01:13, Steve Beaver wrote: > You can concatenate them or just build a new SMPPTS and change the > name in the DDEF > > https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.2.0/com.ibm.zo > s.v2r2.gim2000/dspts1.htm > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Dan Little > Sent: Thursday, March 16, 2017 7:58 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: Can SMPPTS datasets be consolidated? > > I thought the SMMPTSx DDDEF was recorded in the global zone and that > consolidating could not easily be done. > > > Dan > > > On Thu, Mar 16, 2017 at 19:26 Gibney, Dave <gib...@wsu.edu> wrote: > >> Has this always been so. Sometime ago (1.7, 1.9) I had ACCEPT fail >> because I had compressed and moved members into lower sequenced >> SMPPTSn At least I think I remember this. I've just always added >> another SMPPTSz ever since. >> >>> -----Original Message----- >>> From: IBM Mainframe Discussion List >>> [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Jesse 1 Robinson >>> Sent: Thursday, March 16, 2017 3:45 PM >>> To: IBM-MAIN@LISTSERV.UA.EDU >>> Subject: Re: Can SMPPTS datasets be consolidated? >>> >>> SMP/E does not keep a permanent record of which PTS holds a >>> particular sysmod. On every query, the concatenated PTS libraries >>> are searched. If >> the >>> sysmod is found, the particular library is named, otherwise 'not found'. >> This >>> allows you to freely manipulate the libraries and their content. >>> Worst >> case, >>> after consolidating PTS libraries, exit and re-enter the SMP/E dialog. >>> >>> . >>> . >>> J.O.Skip Robinson >>> Southern California Edison Company >>> Electric Dragon Team Paddler >>> SHARE MVS Program Co-Manager >>> 323-715-0595 Mobile >>> 626-543-6132 Office ⇐=== NEW >>> robin...@sce.com >>> >>> >>> -----Original Message----- >>> From: IBM Mainframe Discussion List >>> [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Gibney, Dave >>> Sent: Thursday, March 16, 2017 1:37 PM >>> To: IBM-MAIN@LISTSERV.UA.EDU >>> Subject: (External):Re: Can SMPPTS datasets be consolidated? >>> >>> I am not sure the process. I'd advise adding more secondary PPTS >> datasets. >>> SMP/E remembers which PPTS a given PTF is in. >>> >>>> -----Original Message----- >>>> From: IBM Mainframe Discussion List >>>> [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Allan Staller >>>> Sent: Thursday, March 16, 2017 1:34 PM >>>> To: IBM-MAIN@LISTSERV.UA.EDU >>>> Subject: Re: Can SMPPTS datasets be consolidated? >>>> >>>> YES-----Original Message-----From: IBM Mainframe Discussion List >>>> [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Herring, BobbySent: >>>> Thursday, March 16, 2017 3:30 PMTo: IBM- >>> m...@listserv.ua.EDUSubject: >>>> Can SMPPTS datasets be consolidated?I am in the process of >>>> receiving a large RSU maintenance order. I have filled up three >>>> SMPPTS datasets that were not defined large enough.Can these be >>>> merged and consolidated into one or two much larger datasets?Bobby >>>> HerringTexas Farm Bureau ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN