So when I look at the compiler options, they have DATA(31)

ALL31 in LE is OFF

Only things I can think of for now.

Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of
> Steve Thompson
> Sent: Thursday, January 24, 2019 7:10 PM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Re: Are there compiler options to move Working Storage in Cobol
> above the line?
> 
> DATA(24) may be their problem. But, you can’t change it if csects are
> statically linked that are RMODE 24.
> 
> I’m fixing some issues like this now for ENT COBOL 4.2 where I work. The
> routines are ALC.....
> 
> Sent from my iPhone — small keyboarf, fat fungrs, stupd spell manglr. Expct
> mistaks
> 
> 
> > On Jan 24, 2019, at 8:06 PM, Lizette Koehler <stars...@mindspring.com>
> wrote:
> >
> > A friend of mine is having a bit of problem with a Cobol program.  WS
> > is about 7M in size below the line.  This creates the perfect
> > environment for S878-10 abends.
> >
> > Is there a compiler option that would move WS above the line?  Or is
> > there a different solution.  If there is an option, what level of
> > Cobol did it show up in?
> >
> >
> > No, I do not know what they are doing.  But I am told they cannot
> > change the code.
> >
> > Thanks
> >
> >
> >
> > Lizette Koehler