On Mon, 11 Sep 2006 16:31:04 -0000, Dusha, Cecelia Ms. WHS/ITMD 
<[EMAIL PROTECTED]> wrote:

>q alloc page
>                EXTENT     EXTENT  TOTAL  PAGES   HIGH    %
>VOLID  RDEV      START        END  PAGES IN USE   PAGE USED
>------ ---- ---------- ---------- ------ ------ ------ ----
>510PAG F005          1       3338 600840 332523 443499  55%
>PAG002 F008          1       3337 600660      0      0   0%
>PAG003 F00A          1       3337 600660      0      0   0%
>                                  ------ ------        ----
>SUMMARY                            1760K 332523         18%
>USABLE                             1760K 332523         18%
>Ready; T=0.01/0.01 12:21:38
>
>MDC READS is now 33/SEC...  Could the percentage used be stuck at the hi
gh
>water mark?

HIGH PAGE is the high water mark.  PAGES IN USE is the current usage.  Th
e 
% USED is PAGES IN USE / TOTAL PAGES.  (332523/600840 is 55%.)  So, no, 

it's not stuck at the high water mark.

Brian Nielsen