Hi, PGT003 Explanation: The DASD page slot being released was not previously allocated, or the slot address is incorrect.
User response: By means of the callers return address and base registe r stored in SAVER14 and SAVER12 in the SAVBK located by R13, identify the module attempting to release the page. Locate the source (control block o r ASATE) of the address of the DASD being released to verify that it has no t been destroyed. If the DASD page is in a spool file, it is possible that the file has been incorrectly checkpointed and warm-started after a system shutdown or a system crash. I got 2 PGT003 abends in 2 weeks. And I don't find the reason. All my DASD pages are always allocated with a %>0 and I never changed a s lot address since the install. So I suppose that 'a DASD page is in a spool file' but I don't understand what that means. How to konw that ? And if I do a FORCE start, would it be enough or should I do a COLD start to definitely remove my problem ? Alain Benveniste