Thanks, I will take a look at auditor; the temporary TCPIP outage is not a problem. I have no way other than TCPIP to connect without physically going into our Secure Area where the HMC lives.
-----Original Message----- From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf Of Dave Jones Sent: Friday, July 30, 2010 12:16 PM To: IBMVM@LISTSERV.UARK.EDU Subject: Re: ipl tcpip I think you have two choices here, David. 1) log onto your z/VM system via another path other than TCP/IP, e.g., a locally attached 3270 or OSA ICC. 2) use a utility like AUDITOR (included with z/VM) to automatically xautolog TCPIP after you have forced it off. Of course, this will disrupt your TN3270 session for the length of time it takes for TCPIP to come back up. Have a good one. On 07/30/2010 10:58 AM, Dean, David (I/S) wrote: > How can I remotely bounce TCPIP without using by HMC? I want to send > a command, say from maint, that would shut it down and subsequently > bring it back. > > David M. Dean Information Systems BlueCross BlueShield Tennnessee > > > > ----------------------------------------------------- Please see the > following link for the BlueCross BlueShield of Tennessee E-mail > disclaimer: http://www.bcbst.com/email_disclaimer.shtm > -- Dave Jones V/Soft www.vsoft-software.com Houston, TX 281.578.7544 ----------------------------------------------------- Please see the following link for the BlueCross BlueShield of Tennessee E-mail disclaimer: http://www.bcbst.com/email_disclaimer.shtm