AUDITOR is documented here:

z/VM V5R4.0 CMS Commands and Utilities Reference
(http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/HCSD8B30/CCONTENTS?SHELF=hcsh2aa1&DN=SC24-6073-03&DT=20080630160548)



On 07/30/2010 11:27 AM, Dean, David (I/S) wrote:
Thanks, I will take a look at auditor; the temporary TCPIP outage is not a 
problem.  I have no way other than TCPIP to connect without physically going 
into our Secure Area where the HMC lives.

-----Original Message-----
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf 
Of Dave Jones
Sent: Friday, July 30, 2010 12:16 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: ipl tcpip

I think you have two choices here, David.

1) log onto your z/VM system via another path other than TCP/IP, e.g., a
locally attached 3270 or OSA ICC.
2) use a utility like AUDITOR (included with z/VM) to automatically
xautolog TCPIP after you have forced it off. Of course, this will
disrupt your TN3270 session for the length of time it takes for TCPIP to
come back up.

Have a good one.

On 07/30/2010 10:58 AM, Dean, David (I/S) wrote:
How can I remotely bounce TCPIP without using by HMC?  I want to send
a command, say from maint, that would shut it down and subsequently
bring it back.

David M. Dean Information Systems BlueCross BlueShield Tennnessee



----------------------------------------------------- Please see the
following link for the BlueCross BlueShield of Tennessee E-mail
disclaimer:  http://www.bcbst.com/email_disclaimer.shtm



--
Dave Jones
V/Soft
www.vsoft-software.com
Houston, TX
281.578.7544

Reply via email to