This is a shear guess on my part. Have you tried using OFFLINDR? It is file 719 
on the CBT tape.

http://www.cbttape.org/cbtdowns.htm?showonlynew=false

This program appears to work more like DDR. It does not appear to require an OS 
VTOC.

John McKown
Systems Engineer IV
IT

Administrative Services Group

HealthMarkets(r)

9151 Boulevard 26 * N. Richland Hills * TX 76010
(817) 255-3225 phone * (817)-691-6183 cell
john.mck...@healthmarkets.com * www.HealthMarkets.com

Confidentiality Notice: This e-mail message may contain confidential or 
proprietary information. If you are not the intended recipient, please contact 
the sender by reply e-mail and destroy all copies of the original message. 
HealthMarkets(r) is the brand name for products underwritten and issued by the 
insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake Life Insurance 
Company(r), Mid-West National Life Insurance Company of TennesseeSM and The 
MEGA Life and Health Insurance Company.SM


________________________________
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf 
Of Martin, Terry R. (CMS/CTR) (CTR)
Sent: Thursday, August 12, 2010 9:44 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: DR Backup using DFDSS


Hi

I have a dilemma. All of my z/Linux DASD volumes are formatted for a VTOC on 
cylinder zero so that I can leverage the z/OS DFDSS backups of these volumes. 
No problem, however I am getting this one guest ready for DR and as such 
running DFDSS on z/OS to accomplish this. This particular guest has 2 volumes 
that do not have z/OS VTOC (Dedicating them in the Directory entry) therefore 
DFDSS receives the ADR307E: error message basically because there is no z/OS 
VTOC.

I know I could use DDR on z/VM to get around this but the problem is that these 
volumes are in use and I need to attach them to whatever machine I am going to 
do the DDR from and cannot go to another LPAR because these particular volumes 
were not gen'ed to be accessible from any other LPAR but the production 
(separation requirement).

So is there any way I can get these backed up given the above?

Thanks