Hi, George. On 10/27/2010 09:38 AM, George Henke/NYLIC wrote: > Even though everything finished successfully when I applied maintenance > yesterday, I received some warnings which prompt the following 2 > questions. I have not PUT2PROD yet. > Good, it's always a good idea to double-check everything (just in case you missed something) before doing the PUT2PROD step.
> Question 1: Does the restrictive RMODE cause the RO IFREQ message below > and, if so, do I need to rerun this without the RMODE restriction? > > ************************************************************************ > **** SERVICE USERID: MAINT **** > ************************************************************************ > **** Date: 10/26/10 Time: 18:39:45 **** > ************************************************************************ > WN:DMSLIO994W Restrictive RMODE encountered in CSECT CEEBCKRI. > WN:DMSLIO994W LOAD continues below 16Mb. > RO:VMFAPP2112W PTF UK59535 has a IFREQ requisite for PTF UM33112 in > RO: product 5VMCMS40 (CMS component for z/VM 5.4.0) > NO, you can safely ignore this message. > Question 2: Do I need to copy these objects to the workstation? I don't > think so. > > WN:VMFBDC2250W The following OSA objects have been built on BUILD0 100 > WN: (K) and should be copied to your workstation: > WN:VMFBDC2250W IOAJAVA BIN > WN:VMFBDC2250W The following VMHCD objects have been built on BUILD0 300 > WN: (I) and should be copied to your workstation: > WN:VMFBDC2250W EEQINSTX EXEBIN > > You need to downland to your workstation these updated files only if you are also running OSA/SF GUI feature (IOAJAVA BIN) or the workstation (PC) component of the HCM (EEOINSTX EXEBIN). -- Dave Jones V/Soft Software www.vsoft-software.com Houston, TX 281.578.7544