Hi, George.

On 10/27/2010 09:38 AM, George Henke/NYLIC wrote:
> Even though everything finished successfully when I applied maintenance 
> yesterday, I received some warnings which prompt the following 2 
> questions.  I have not PUT2PROD yet.
> 
Good, it's always a good idea to double-check everything (just in case
you missed something) before doing the PUT2PROD step.

> Question 1:  Does the restrictive RMODE cause the RO IFREQ message below 
> and, if so, do I need to rerun this without the RMODE restriction?
> 
> ************************************************************************ 
> ****             SERVICE               USERID: MAINT                **** 
> ************************************************************************ 
> ****            Date: 10/26/10            Time: 18:39:45            **** 
> ************************************************************************ 
> WN:DMSLIO994W Restrictive RMODE encountered in CSECT CEEBCKRI. 
> WN:DMSLIO994W LOAD continues below 16Mb. 
> RO:VMFAPP2112W PTF UK59535 has a IFREQ requisite for PTF UM33112 in 
> RO:            product 5VMCMS40 (CMS component for z/VM 5.4.0) 
> 

NO, you can safely ignore this message.
> Question 2:  Do I need to copy these objects to the workstation?  I don't 
> think so.
> 
> WN:VMFBDC2250W The following OSA objects have been built on BUILD0 100 
> WN:            (K) and should be copied to your workstation: 
> WN:VMFBDC2250W IOAJAVA  BIN 
> WN:VMFBDC2250W The following VMHCD objects have been built on BUILD0 300 
> WN:            (I) and should be copied to your workstation: 
> WN:VMFBDC2250W EEQINSTX EXEBIN 
> 
> 
You need to downland to your workstation these updated files only if you
are also running OSA/SF GUI feature (IOAJAVA BIN) or the workstation
(PC) component of the HCM (EEOINSTX EXEBIN).
-- 
Dave Jones
V/Soft Software
www.vsoft-software.com
Houston, TX
281.578.7544

Reply via email to