On 1/11/2022 8:19 PM, Tony King wrote:
I had one of those on an O-200 and Jeff is right, there are 4 CHT/EGT channels 
in total

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

I am thinking it might be a fun mental exercise to make a circuit using two small 4 pole relays

OMRON INDUSTRIAL AUTOMATION MY4 AC24 (S)

and a SP/DT switch that would allow me to monitor all 4 cylinders with CHT "AND" EGT by simply flipping one switch back and forth between CHT and EGT.  The two relays would give me 8 contacts when they are not energized and another 8 contacts when they are energized.  I'd have them read CHT when de-energized as I'd consider that more critical.  As the information is not "flight critical" (it won't cause me to crash if it fails) I'll give it some thought.  Is this a "crash on takeoff" idea or does it have merit?  There is probably a major flaw here somewhere.

Larry Flesner