Donald Becker wrote:
> 10baseT is so robust that I've seen it work over miswired cables that had no
> DC connection, only the mispaired cables acting as a 1:1 transformer.
And I've seen 10BaseT working with a cable with a damaged connector
where one pin didn't make contact.
> But when you negotiate up to 100baseTx the link stops working.
And that is basically a pitfall or misfeature of the autonegotiation,
namely that the negotiation takes place in a robust modulation format
and then the card tries to switch to a less robust mode.
Tom
-
To unsubscribe from this list: send the line "unsubscribe linux-net" in
the body of a message to [EMAIL PROTECTED]