On Wed, May 04, 2011 at 08:40:06PM +0200, Peter Kümmel wrote:
> On 04.05.2011 20:34, Enrico Forestieri wrote:
> >On Wed, May 04, 2011 at 08:21:18PM +0200, Peter Kümmel wrote:
> >>On 04.05.2011 19:38, Enrico Forestieri wrote:
> >>>- Missing ability to kill converters if they got stalled. You have to
> >>>   wait for a timeout and cannot kill them because they are in a thread
> >>>   of your same process.
> >>
> >>I don't know if I understand this, but also processes created by
> >>QProcess could be killed.
> >
> >I was talking about the converters started for preview/export. They run
> >in a thread and don't appear in the task manager on Windows or in a
> >"ps -ef" on *nix. I was recently bitten by this and had to wait for
> >30 minutes before I could continue the work without killing lyx itself.
> >As bloat calls for other bloat, maybe a thread manager that allows to
> >forcibly quit stalled threads is in order :)
> >
> 
> And in LyX 1.6 the converters where forked, so you could kill them?

Exactly.

> I am innocent! ;)

Then you can sleep the sleep of the just :)

-- 
Enrico