I have two different APC units... uhidev0 at uhub1 port 1 configuration 1 interface 0 "American Power Conversion Smart-UPS 1500 FW:601.3.D USB FW:1.3" rev 1.10/0.06 addr 2 uhidev0: iclass 3/0, 54 report ids upd0 at uhidev0 $ sysctl | grep upd hw.sensors.upd0.indicator0=Off (Charging), OK hw.sensors.upd0.indicator1=Off (Discharging), OK hw.sensors.upd0.indicator2=On (ACPresent), OK hw.sensors.upd0.indicator3=On (BatteryPresent), OK hw.sensors.upd0.indicator4=Off (ShutdownImminent), OK hw.sensors.upd0.percent0=100.00% (FullChargeCapacity), OK hw.sensors.upd0.percent1=100.00% (RemainingCapacity), OK
uhidev0 at uhub7 port 2 configuration 1 interface 0 "APC Back-UPS ES 550G FW:904.W1 .D USB FW:W1" rev 1.10/1.06 addr 2 uhidev0: iclass 3/0, 123 report ids upd0 at uhidev0 $ sysctl | grep upd hw.sensors.upd0.indicator0=Off (Charging), OK hw.sensors.upd0.indicator1=Off (Discharging), OK hw.sensors.upd0.indicator2=On (ACPresent), OK hw.sensors.upd0.indicator3=On (BatteryPresent), OK hw.sensors.upd0.indicator4=Off (ShutdownImminent), OK hw.sensors.upd0.percent0=100.00% (RemainingCapacity), OK hw.sensors.upd0.percent1=100.00% (FullChargeCapacity), OK > -----Original Message----- > From: [email protected] [mailto:[email protected]] On Behalf Of > David Higgs > Sent: Friday, November 28, 2014 9:43 AM > To: [email protected] > Subject: Re: sensorsd, upd, and state changes > > Do you mind saying what type of USB you have, and what these sensors map > are for your hardware? > > I have: > uhidev0 at uhub1 port 2 configuration 1 interface 0 "American Power > Conversion Back-UPS ES 750 FW:841.I3 .D USB FW:I3" rev 1.10/1.01 addr > 2 > uhidev0: iclass 3/0, 146 report ids > upd0 at uhidev0 > > Which only appears to provide: > hw.sensors.upd0.indicator3=Off (ShutdownImminent), OK