Bryan Vyhmeister a icrit :
On Apr 16, 2007, at 1:58 AM, Ronnie Garcia wrote:

Clint Pachl a icrit :
Ronnie Garcia wrote:
Do you expect doing more than 100mbits with this hadware (with PF anabled) ? I'm maxing a P4 2.4Ghz at 40mbits, with a dual em, and a ~300 lines pf.conf
What is your packets/sec when your pushing 40Mbs? Does the traffic flow in one em and out the other or is the dual em in a trunk (i.e. 2Gbs)?

Traffic gets in one em, is filtered by pf, and gets out from the other em (and the other way around). Its doing 11kpps in and 6kpps out of each em, plus 7kpps on the pfsync interface, which is a sis

This brings up a question I have had for a while. Does pfsync generate enough traffic that running gigabit cards for your $ext_if and $int_if and a 100base-TX card for your pfsync interface cause a major bottleneck?

It depends on the rate of the states changes.
Here, we have ~30mbits on pfsync, for ~40mbits of traffic (!)

--
Ronnie Garcia <r.garcia at ovea dot com>