You can't.

So instead if I see an 85C result, I issue the fix code and read again.

It's inconsequential in the scheme of things.

Eric Vickery wrote:
> An 85 is returned if the temperature conversion had a problem or is not 
> finished 
> yet. The problem is how can you tell when it is a good reading of 85.
> 
> Eric
> 


-------------------------------------------------------------------------