Hi, I have a may the same problem, but not on a restore. It''s on a new installation of quadstore, i'v created a tape library IBM TS3100 on Quadstor. When i try to vary off the library no problem, when i try to vary on the tape of the library after vary off mlb device, i've got the message, that the device is in use by another LPAR, but i've just one LPAR.
TAPMLB06 EN FONCTION TAP08 OPERATIONNELLE NON PROTEGEE TAP09 OPERATIONNELLE NON PROTEGEE ID message . . . . . . : CPD8EB4 Date d'envoi . . . . . : 15/06/23 Heure d'envoi . . . . : 16:09:25 Message . . . . : La mise en fonction de l'unité TAP08 a échoué. Cause . . . . . : Cette unité de bande est attribuée à un autre système. Que faire . . . : Attendez que l'autre système ait fini de l'utiliser, puis renouvelez votre demande. Unité TAPMLB06 mise hors fonction. La mise en fonction de l'unité TAP08 a échoué. Commande de changement d'état non exécutée. I've trie on V7R4 and V7R2 with latest PTF. Seems that QUANTUM DRIVE are correctly work wih BRMS but can't backup on VTL cardridge... Thank You Le mardi 6 juin 2023 à 10:09:31 UTC+2, quadstor a écrit : > Hi, > > Have you checked if the drive status is UNPROTECTED ? Please review > https://www.ibm.com/docs/en/i/7.2?topic=libraries-sharing-tape-library-resources > > What is the output of WRKDEVSTS ? > Please attach the diagnostic logs from the VTL system and also mention the > time of the device in use error message > > > > On Mon, Jun 5, 2023 at 6:47 PM roopa shree <rupa...@gmail.com> wrote: > >> I am trying to do a full restore of the IBM i using the back up from >> the VTL >> >> 1. Launched a new LPAR using IBM provided images on the IBM cloud >> 2. Tried to attach the same tapelibrary of the system which we are trying >> to restore >> 3. Varied off the tape library on the main LPAR and tried to configure >> same library on the new LPAR but was getting error that the device is in >> use >> 4. Tried to configure a new tape library and attach the vcatridges but >> still was unable to >> >> So is there any where I am going wrong or is there otherway to do a full >> system restore >> >> -- >> You received this message because you are subscribed to the Google Groups >> "QUADStor VTL" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to quadstor-vtl...@googlegroups.com. >> To view this discussion on the web visit >> https://groups.google.com/d/msgid/quadstor-vtl/48bab5c1-5fee-48d4-abd6-7fa85ba3c7cfn%40googlegroups.com >> >> <https://groups.google.com/d/msgid/quadstor-vtl/48bab5c1-5fee-48d4-abd6-7fa85ba3c7cfn%40googlegroups.com?utm_medium=email&utm_source=footer> >> . >> > -- You received this message because you are subscribed to the Google Groups "QUADStor VTL" group. To unsubscribe from this group and stop receiving emails from it, send an email to quadstor-vtl+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/quadstor-vtl/d44e94e9-c2f1-49b3-9e97-07e1ef80b073n%40googlegroups.com.