GE M-pro pin out on the top of the power supply there are 2 terminal
strips tb501 and tb 502, tb502-2=rxa, tb502-10=ptt/lo, tb502-12=txa,
tb502-16=cas/hi - the cas is next to 110vac so be really smart and pull
the plug from the wall before you tinker with that one.
Russell Filling wrote:
>
> ok im trying to hook the rc 1k up to the old GE crate ..
> the old controller box had a barrier strip with fork blades and scre
> term on it the rc 1k had a DB 25 , i followed the pinouts per
> audio from rec , and audio to TX , ptt , and COS line , but what im
> having problems with is the blue and white wires for the ptt
> interlock disable off the repeater , , and when i turn the rc1k on the
> tx light on the tx disable module comes on but now ive lost all
> functionality of a repeater , and i dont hace a service mic to see if i
> can key the crate back up....... how the hell does that intlerlock
> work , does it need to be grounded ? does it need the reg 12.6 v+ ?
> and im not even sure if i have the right COS line , the old club
> tech from the other club hasnt touched it in $ yrs and doesnt remember
> it at all !!!! , sooooooo anyone out ther could ya help me ??? im
> kinda lost considering this is the first ever repeater of GE ive
> ever worked on and this is the first RC1K ive worked on , its a it
> different than the old cat 300's and motorola mocoms heheheh
>
>
> Yahoo! Groups Links
>
>
>
>
--
73...Clark Beckman N8PZD
Pursuant to U.S. Code, title 47, Chapter 5, Subchapter II, �227,
"Any and all nonsolicited commercial E-mail sent to this address
is subject to a download and archival fee of $500.00 U.S.".
E-mailing denotes acceptance of these terms.
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/Repeater-Builder/
<*> To unsubscribe from this group, send an email to:
[EMAIL PROTECTED]
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/