Re: [Freesurfer] ReRunning Subjects in Newer FreeSurfer Versions and ICV Differences

2011-06-17 Thread Bruce Fischl
Hi Jeff,

in most cases that won't run anything. -make all will check the 
timestamps on the various volumes/surface and only rerun things in cases 
where something further back in the stream has a newer timestamp than 
something newer. You need to run it with -all

cheers
Bruce

On Thu, 16 Jun 2011, Jeff Sadino wrote:

 Hello Bruce,

 Thank you for your reply.  I used recon-all -make all -s subject.

 Thanks,
 Jeff

 On Thu, Jun 16, 2011 at 3:11 PM, Bruce Fischl 
 fis...@nmr.mgh.harvard.eduwrote:

 Hi Jeff

 what command did you run to run them over?

 cheers
 Bruce

 On Thu, 16 Jun 2011, Jeff Sadino wrote:

  Hello,

 When FS5 came out, I copied over my FS4 reconstructions to my FS5 Subjects
 Directory, and then reran them using the FS5 recon-all stream.  This
 updated
 their subject folders with the FS5 changes, but not in as many places as I
 would have thought.  For example, on 6 test subjects, I created their FS5
 folders from FS4 folders that I copied over and then ran the FS5 recon-all
 stream.  I also created another copy of their FS5 folders from scratch.
  The
 average difference in their ICV values was -12,000 mm^3.  Is it to be
 expected that FS5 reconstructions running on FS4 folders will not include
 all possible improvements?  If I want to get an accurate an ICV
 measurement
 as possible, is it advisable to rerun all of my subjects in FS5, starting
 from scratch?

 As always, thank you for your valuable assistance!
 Jeff Sadino



 The information in this e-mail is intended only for the person to whom it
 is
 addressed. If you believe this e-mail was sent to you in error and the
 e-mail
 contains patient information, please contact the Partners Compliance
 HelpLine at
 http://www.partners.org/complianceline . If the e-mail was sent to you in
 error
 but does not contain patient information, please contact the sender and
 properly
 dispose of the e-mail.



___
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


[Freesurfer] ReRunning Subjects in Newer FreeSurfer Versions and ICV Differences

2011-06-16 Thread Jeff Sadino
Hello,

When FS5 came out, I copied over my FS4 reconstructions to my FS5 Subjects
Directory, and then reran them using the FS5 recon-all stream.  This updated
their subject folders with the FS5 changes, but not in as many places as I
would have thought.  For example, on 6 test subjects, I created their FS5
folders from FS4 folders that I copied over and then ran the FS5 recon-all
stream.  I also created another copy of their FS5 folders from scratch.  The
average difference in their ICV values was -12,000 mm^3.  Is it to be
expected that FS5 reconstructions running on FS4 folders will not include
all possible improvements?  If I want to get an accurate an ICV measurement
as possible, is it advisable to rerun all of my subjects in FS5, starting
from scratch?

As always, thank you for your valuable assistance!
Jeff Sadino
___
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.


Re: [Freesurfer] ReRunning Subjects in Newer FreeSurfer Versions and ICV Differences

2011-06-16 Thread Bruce Fischl
Hi Jeff

what command did you run to run them over?

cheers
Bruce
On Thu, 16 Jun 2011, Jeff Sadino 
wrote:

 Hello,

 When FS5 came out, I copied over my FS4 reconstructions to my FS5 Subjects
 Directory, and then reran them using the FS5 recon-all stream.  This updated
 their subject folders with the FS5 changes, but not in as many places as I
 would have thought.  For example, on 6 test subjects, I created their FS5
 folders from FS4 folders that I copied over and then ran the FS5 recon-all
 stream.  I also created another copy of their FS5 folders from scratch.  The
 average difference in their ICV values was -12,000 mm^3.  Is it to be
 expected that FS5 reconstructions running on FS4 folders will not include
 all possible improvements?  If I want to get an accurate an ICV measurement
 as possible, is it advisable to rerun all of my subjects in FS5, starting
 from scratch?

 As always, thank you for your valuable assistance!
 Jeff Sadino

___
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.



Re: [Freesurfer] ReRunning Subjects in Newer FreeSurfer Versions and ICV Differences

2011-06-16 Thread Jeff Sadino
Hello Bruce,

Thank you for your reply.  I used recon-all -make all -s subject.

Thanks,
Jeff

On Thu, Jun 16, 2011 at 3:11 PM, Bruce Fischl fis...@nmr.mgh.harvard.eduwrote:

 Hi Jeff

 what command did you run to run them over?

 cheers
 Bruce

 On Thu, 16 Jun 2011, Jeff Sadino wrote:

  Hello,

 When FS5 came out, I copied over my FS4 reconstructions to my FS5 Subjects
 Directory, and then reran them using the FS5 recon-all stream.  This
 updated
 their subject folders with the FS5 changes, but not in as many places as I
 would have thought.  For example, on 6 test subjects, I created their FS5
 folders from FS4 folders that I copied over and then ran the FS5 recon-all
 stream.  I also created another copy of their FS5 folders from scratch.
  The
 average difference in their ICV values was -12,000 mm^3.  Is it to be
 expected that FS5 reconstructions running on FS4 folders will not include
 all possible improvements?  If I want to get an accurate an ICV
 measurement
 as possible, is it advisable to rerun all of my subjects in FS5, starting
 from scratch?

 As always, thank you for your valuable assistance!
 Jeff Sadino



 The information in this e-mail is intended only for the person to whom it
 is
 addressed. If you believe this e-mail was sent to you in error and the
 e-mail
 contains patient information, please contact the Partners Compliance
 HelpLine at
 http://www.partners.org/complianceline . If the e-mail was sent to you in
 error
 but does not contain patient information, please contact the sender and
 properly
 dispose of the e-mail.


___
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.