RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-12 Thread Stan Hoeppner

  I would never have considered running AMDs in a 1u rack
 mount regardless.
  but if you did, I could see that heat could become a small problem,
  especially if you cramming a few high speed HDDs into that
 small space as
  well.  Satndard mini tower with front and back fans seems
 to run at room
  temp in our data centre.

 Difference is, we cant afford to waste rack space on towers :)


Go here:

http://www.racksaver.com/products/RS1100Matrix.asp

And read this:

http://www.racksaver.com/clusters/index.asp

So, apparently RackSaver has no problem integrating 2 Athlon MPs into a 1U
chassis.  And, they offer a choice of motherboards in the 1U chassis, so
apparently they've created a few custom cooling solutions for Athlon MP in
1U, due to the different motherboard layouts.  If they're stuffing standard
19 racks full of the 1U dual Athlon MP servers to create supercomputing
clusters, I'd guarantee they've worked out any thermal issues.

StanTheMan
TheHardwareFreak
http://www.hardwarefreak.com
rcon admin at:
Beer for Breakfast servershttp://bfb.bogleg.org/
   209.41.98.2:27016 (CS multi-map)   209.41.98.2:27015 (DoD)
   209.41.98.2:27017 (CS militia/dust2)Dallas, TX

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: [hlds_linux] RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-12 Thread Stan Hoeppner

 Anyone out there using TEC modules (Thermo-electric cooling
 AKA Peltier
 device) ? I am really looking into it for a dual P3 system.

About the only people using peltiers are serious overclockers.  If you put
them inside a server (especially a small one like 1U or 2U), they'll have to
be powered from the internal power supply on the 12v rail.  Peltiers suck a
bit of power, and with a ~200-250W PSU in a 1U/2U server, your peltiers will
take a fair percentage of that available power.

Keep in mind that CPUs die very quickly if the fan on the hot side of the
peltier fails.  This could even be a potential fire hazard

I'd definitely stay away from peltiers in a server application.

StanTheMan
TheHardwareFreak
http://www.hardwarefreak.com
rcon admin at:
Beer for Breakfast servershttp://bfb.bogleg.org/
   209.41.98.2:27016 (CS multi-map)   209.41.98.2:27015 (DoD)
   209.41.98.2:27017 (CS militia/dust2)Dallas, TX

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-12 Thread Oscar
There are lot of 1U servers that run dual AMD's. Can't understand why some of
you don't think it's any good. Sure there is some cost to develop the 1U
chassis and the one who has to pay is the customer. But if you need the space
to other things, well then there's really not much to do than to pay...

This is a pretty cool server, dual amd's and 4 U160 drives in 1U. oh, and there
is also a cd included :P
http://www.anandtech.com/IT/showdoc.html?i=1514p=1



Quoting Stan Hoeppner [EMAIL PROTECTED]:


   I would never have considered running AMDs in a 1u rack
  mount regardless.
   but if you did, I could see that heat could become a small problem,
   especially if you cramming a few high speed HDDs into that
  small space as
   well.  Satndard mini tower with front and back fans seems
  to run at room
   temp in our data centre.
 
  Difference is, we cant afford to waste rack space on towers :)


 Go here:

 http://www.racksaver.com/products/RS1100Matrix.asp

 And read this:

 http://www.racksaver.com/clusters/index.asp

 So, apparently RackSaver has no problem integrating 2 Athlon MPs into a 1U
 chassis.  And, they offer a choice of motherboards in the 1U chassis, so
 apparently they've created a few custom cooling solutions for Athlon MP in
 1U, due to the different motherboard layouts.  If they're stuffing standard
 19 racks full of the 1U dual Athlon MP servers to create supercomputing
 clusters, I'd guarantee they've worked out any thermal issues.

 StanTheMan
 TheHardwareFreak
 http://www.hardwarefreak.com
 rcon admin at:
 Beer for Breakfast servershttp://bfb.bogleg.org/
209.41.98.2:27016 (CS multi-map)   209.41.98.2:27015 (DoD)
209.41.98.2:27017 (CS militia/dust2)Dallas, TX

 ___
 To unsubscribe, edit your list preferences, or view the list archives, please
 visit:
 http://list.valvesoftware.com/mailman/listinfo/hlds_linux



/Mvh Oscar


This mail was sent from www.bhood.nu
___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: [hlds_linux] RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-12 Thread Stan Hoeppner

 You'll need (stan?) about 3x the airflow to keep this monster
 at a decent temperature.

I won't even guess at a ratio.  I just wouldn't run peltiers in a server at
all, especially a 1U or 2U.

 Most Peltier using overclockers tend to couple them with
 water cooling as its
 heat carrying capacity is significantly greater than air.

True.  However, the k00l'st I've seen is an evaporative cooling tower (think
3 Mile Island):

http://www.overclockers.com/articles389/index03.asp

StanTheMan
TheHardwareFreak
http://www.hardwarefreak.com
rcon admin at:
Beer for Breakfast servershttp://bfb.bogleg.org/
   209.41.98.2:27016 (CS multi-map)   209.41.98.2:27015 (DoD)
   209.41.98.2:27017 (CS militia/dust2)Dallas, TX

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-11 Thread David Touitou
Quoting Adam Hobbs [EMAIL PROTECTED]:

  As long as heat/power is not an issue.
  8-))

 When has heat ever been an issue in an airconditioned rack in an
 climate controlled data centre?

Having 19°C in the rack and in the datacentre is nice.

Having more than 70°C in the 1U case (or even 2U), because of two
Athlon 2000MP and not enough fans in the case is not nice.

In the same datacentre (19°C) my servers are, they ae some servers
constantly beeping in alert for fresh air...

David.

--
http://gamez.solexine.fr/

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-10 Thread Adam Hobbs


 As long as heat/power is not an issue.
 8-))

 David.

 --


When has heat ever been an issue in an airconditioned rack in an climate
controlled data centre?

:)

mentasm

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-10 Thread Jeremy Brooking
On Mon, 2002-11-11 at 15:40, Adam Hobbs wrote:
 When has heat ever been an issue in an airconditioned rack in an climate
 controlled data centre?


regardless of how well cooled you rack is, internal case temps need kept
down.

We have just had to upgrade to a 2u case from a 1u with a dual amd
system we had to increase cooling (and this is a floor forced aircon
rack, in a temp controlled room).

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-10 Thread Adam Hobbs


 On Mon, 2002-11-11 at 15:40, Adam Hobbs wrote:
  When has heat ever been an issue in an airconditioned rack in an climate
  controlled data centre?


 regardless of how well cooled you rack is, internal case temps need kept
 down.

 We have just had to upgrade to a 2u case from a 1u with a dual amd
 system we had to increase cooling (and this is a floor forced aircon
 rack, in a temp controlled room).


Sorry,

I would never have considered running AMDs in a 1u rack mount regardless.
but if you did, I could see that heat could become a small problem,
especially if you cramming a few high speed HDDs into that small space as
well.  Satndard mini tower with front and back fans seems to run at room
temp in our data centre.

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux



RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?

2002-11-10 Thread Kevin J. Anderson
untill that climate controlled area breaks

I had to clean up at a client where that happened once.  was not a pretty
sight trying to restore the data when we had no documentation on how the
servers were set up.  and no, we were not the ones in control of the servers
before the air conditioning blew.

kev

-Original Message-
From: [EMAIL PROTECTED]
[mailto:hlds_linux-admin;list.valvesoftware.com]On Behalf Of Adam Hobbs
Sent: Sunday, November 10, 2002 9:41 PM
To: [EMAIL PROTECTED]
Subject: RE: P3 vs P4 vs Athlon was: Re: [hlds_linux] CPU Usage?




 As long as heat/power is not an issue.
 8-))

 David.

 --


When has heat ever been an issue in an airconditioned rack in an climate
controlled data centre?

:)

mentasm

___
To unsubscribe, edit your list preferences, or view the list archives,
please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux

___
To unsubscribe, edit your list preferences, or view the list archives, please visit:
http://list.valvesoftware.com/mailman/listinfo/hlds_linux