RE: [iagi-net-l] AMD Issue
Maksudnya Acid Mine Drainage? Walupun pertanyaan ditujukan spesifik buat orang KPC, mungkin saya bisa membantu ya? Ini saya "copy paste" saja ya? Scope of target AMD study: 1. Rock samples analysis (static test): * Total sulphur contents * Acid Neutralizing Capacity/ANC * Net Acid generating (NAG test) * Minerals content especially for PAF (Potential Acid Forming) materials * Determining the Maximum Potential Acidity (MPA) * Determining the Net Acid Producing Potential (NAPP) * Weight of each samples - 1 kg 2. Potential AMD analysis - classification of NAF (Non Acid Forming) and PAF (Potential Acid Forming) materials 3. AMD impacts assessment and mitigations strategies for AMDAL purpose (ANDAL, RKL and RPL). Samples were collected from the base of the weathered zone (grey shale) to at least 0.5m below the expected pit floor i.e. below the lowest seam. Samples and data required from site: * Minimum from 2 drill holes * Fresh core samples and immediately to be conservation (by "plastic warp" in order to avoid the samples direct contact with air and sunshine) in order to not oxidizing. * Number samples depending number of materials/rock types that determined based on the lithology of each drill holes. Approximately 20 samples would be taken from two drill holes (10 samples per holes). * Priority - samples taken from overburden and inter-burden based on the lithology of each drill hole sampled as follows: * Immediate roof and immediate floor or each seams include the bottom seam that will be mined * Carbonaceous clay/shale * Clay * Sand/siltstone * Weigh of each samples - 1 kg salam, SLAMET RIYADI -Original Message- From: Yan Adriansyah [mailto:[EMAIL PROTECTED] Sent: Thursday, December 22, 2005 8:02 AM To: iagi-net@iagi.or.id Subject: [iagi-net-l] AMD Issue Dear Bapak-Ibu, Barangkali ada yang bisa memberikan sharing informasi mengenai AMD, adapun informasi yang kami perlukan adalah : 1. Teknik sampling: coring atau open hole, interval, kedalaman dan jenis litologi apa yang berpotensi menjadi PAF, apakah sampling harus mencapai hingga final pit bottom elevation ?. 2. Penempatan material PAF ini dalam area dumping/disposal. 3. Kemana harus saya kirim sample ini untuk dianalisis, maklum company kami tidak memiliki lab. yang support utk pekerjaan ini seperti halnya yang ada di KPC. 4. Spasi drilling sehingga coverage area yang kita ambil sample-nya cukup memadai untuk analisis ini. Sebagai gambaran bahwa dip lapisan di area tambang kami bervariasi antara 30 - 50 degree dengan jenis litologi sandstone, mudstone dan tentunya coal. Semoga para sesepuh AMD di KPC bisa memberikan pencerahan untuk hal ini. Demikian dan terima kasih Salam YN This message and any attached files may contain information that is confidential and/or subject of legal privilege intended only for use by the intended recipient. If you are not the intended recipient or the person responsible for delivering the message to the intended recipient, be advised that you have received this message in error and that any dissemination, copying or use of this message or attachment is strictly forbidden, as is the disclosure of the information therein. If you have received this message in error please notify the sender immediately and delete the message. - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geologi : Aria A. Mulhadiono(anugraha[at]centrin.net.id) -
RE: [iagi-net-l] AMD Issue
Tunggu aja sebentar Pren, Baru minggu lalu kita susun rancangan SNI untuk Penanganan AMD dan Pengujiannya Ntar juga ada undangan untuk konsensusnya M Munir Zein Damar Pandulu AMD & Geotechnical Section PT KALTIM PRIMA COAL -Original Message- From: Riyadi, Slamet S [mailto:[EMAIL PROTECTED] Sent: Thursday, 22 December 2005 8:46 AM To: iagi-net@iagi.or.id Subject: RE: [iagi-net-l] AMD Issue Maksudnya Acid Mine Drainage? Walupun pertanyaan ditujukan spesifik buat orang KPC, mungkin saya bisa membantu ya? Ini saya "copy paste" saja ya? Scope of target AMD study: 1. Rock samples analysis (static test): * Total sulphur contents * Acid Neutralizing Capacity/ANC * Net Acid generating (NAG test) * Minerals content especially for PAF (Potential Acid Forming) materials * Determining the Maximum Potential Acidity (MPA) * Determining the Net Acid Producing Potential (NAPP) * Weight of each samples - 1 kg 2. Potential AMD analysis - classification of NAF (Non Acid Forming) and PAF (Potential Acid Forming) materials 3. AMD impacts assessment and mitigations strategies for AMDAL purpose (ANDAL, RKL and RPL). Samples were collected from the base of the weathered zone (grey shale) to at least 0.5m below the expected pit floor i.e. below the lowest seam. Samples and data required from site: * Minimum from 2 drill holes * Fresh core samples and immediately to be conservation (by "plastic warp" in order to avoid the samples direct contact with air and sunshine) in order to not oxidizing. * Number samples depending number of materials/rock types that determined based on the lithology of each drill holes. Approximately 20 samples would be taken from two drill holes (10 samples per holes). * Priority - samples taken from overburden and inter-burden based on the lithology of each drill hole sampled as follows: * Immediate roof and immediate floor or each seams include the bottom seam that will be mined * Carbonaceous clay/shale * Clay * Sand/siltstone * Weigh of each samples - 1 kg salam, SLAMET RIYADI -Original Message- From: Yan Adriansyah [mailto:[EMAIL PROTECTED] Sent: Thursday, December 22, 2005 8:02 AM To: iagi-net@iagi.or.id Subject: [iagi-net-l] AMD Issue Dear Bapak-Ibu, Barangkali ada yang bisa memberikan sharing informasi mengenai AMD, adapun informasi yang kami perlukan adalah : 1. Teknik sampling: coring atau open hole, interval, kedalaman dan jenis litologi apa yang berpotensi menjadi PAF, apakah sampling harus mencapai hingga final pit bottom elevation ?. 2. Penempatan material PAF ini dalam area dumping/disposal. 3. Kemana harus saya kirim sample ini untuk dianalisis, maklum company kami tidak memiliki lab. yang support utk pekerjaan ini seperti halnya yang ada di KPC. 4. Spasi drilling sehingga coverage area yang kita ambil sample-nya cukup memadai untuk analisis ini. Sebagai gambaran bahwa dip lapisan di area tambang kami bervariasi antara 30 - 50 degree dengan jenis litologi sandstone, mudstone dan tentunya coal. Semoga para sesepuh AMD di KPC bisa memberikan pencerahan untuk hal ini. Demikian dan terima kasih Salam YN This message and any attached files may contain information that is confidential and/or subject of legal privilege intended only for use by the intended recipient. If you are not the intended recipient or the person responsible for delivering the message to the intended recipient, be advised that you have received this message in error and that any dissemination, copying or use of this message or attachment is strictly forbidden, as is the disclosure of the information therein. If you have received this message in error please notify the sender immediately and delete the message. - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geologi : Aria A. Mulhadiono(anugraha[at]centrin.net.id) - DISCLAIMER: This message and any attachments may contain privileged information. Any unauthorised use of this message by any person may lead to legal consequences. Any views expressed in this message are those of the individual sender and may not neces
RE: [iagi-net-l] AMD Issue
Mas Yan, apa kabar? Kalau boleh sedikit urun rembug. Untuk pengambilan sample AMD biasanya sih tergantung struktur yang berkembang di daerah tersebut. Semakin banyak struktur yang berkembang berarti semakin rapat pengambilan sample antar lobang bor. Jenis lobang bornya tidak jadi masalah, yang penting penanganannya harus secepatnya dilakukan analisa untuk mengurangi pengarus oksidasi, atau kalau sample dikirim ke lab independent ya berarti sample harus dibungkus sedemikian rupa hingga meminimalisasi adanya pengaruh dari luar. Kalau mau tepat sekali sih memang sample lobang inti lebih bagus daripada sample lobang terbuka. Pengambilan sample akan lebih bagus kalau sampai sedikit dibawah seam target agar kita tahu keseluruhan type AMD yang akan kita tambang. Untuk jenis litologi yang berpotensi menjadi PAF sepertinya tidak bisa dipastikan begitu saja, karena tergantung dari komposisi mineral pembentuk batuan pada waktu proses pengendapan yang terjadi. Biasanya untuk daerah tertentu 60-80% litologi pembentuk PAF-nya sama. Material PAF ini biasanya ditempatkan dibagian bawah hingga tengah lokasi dumping, sedangkan material NAF di tempatkan di pinggir dan atas lokasi dumping, biasa Mas... untuk mengurangi keasaman secara natural, disamping biasanya ditambah juga bahan-bahan lain agar air yang melewati daerah ini tetap aman. Mudah-mudahan bisa membantu dan tidak tambah membuat pusing... (Pak Damar dan Pak Deddi di Sangatta mungkin bisa menambahkan biar lebih gambling) Salam Ewa Rappe -Original Message- From: Yan Adriansyah [mailto:[EMAIL PROTECTED] Sent: Thursday, December 22, 2005 9:02 AM To: iagi-net@iagi.or.id Subject: [iagi-net-l] AMD Issue Dear Bapak-Ibu, Barangkali ada yang bisa memberikan sharing informasi mengenai AMD, adapun informasi yang kami perlukan adalah : 1. Teknik sampling: coring atau open hole, interval, kedalaman dan jenis litologi apa yang berpotensi menjadi PAF, apakah sampling harus mencapai hingga final pit bottom elevation ?. 2. Penempatan material PAF ini dalam area dumping/disposal. 3. Kemana harus saya kirim sample ini untuk dianalisis, maklum company kami tidak memiliki lab. yang support utk pekerjaan ini seperti halnya yang ada di KPC. 4. Spasi drilling sehingga coverage area yang kita ambil sample-nya cukup memadai untuk analisis ini. Sebagai gambaran bahwa dip lapisan di area tambang kami bervariasi antara 30 - 50 degree dengan jenis litologi sandstone, mudstone dan tentunya coal. Semoga para sesepuh AMD di KPC bisa memberikan pencerahan untuk hal ini. Demikian dan terima kasih Salam YN - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geologi : Aria A. Mulhadiono(anugraha[at]centrin.net.id) - - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geologi : Aria A. Mulhadiono(anugraha[at]centrin.net.id) -
Re: [iagi-net-l] AMD Issue
Pak Riyadi dan eks kolega saya di KPC, Terima kasih atas sharing informasinya, namun ada satu yang terlewat kira2 ke lab. mana sample tsb harus saya kirim ? (point pertanyaan No. 3 saya). Salam YN - Original Message - From: "Riyadi, Slamet S" <[EMAIL PROTECTED]> To: Sent: Thursday, December 22, 2005 8:46 AM Subject: RE: [iagi-net-l] AMD Issue Maksudnya Acid Mine Drainage? Walupun pertanyaan ditujukan spesifik buat orang KPC, mungkin saya bisa membantu ya? Ini saya "copy paste" saja ya? Scope of target AMD study: 1. Rock samples analysis (static test): * Total sulphur contents * Acid Neutralizing Capacity/ANC * Net Acid generating (NAG test) * Minerals content especially for PAF (Potential Acid Forming) materials * Determining the Maximum Potential Acidity (MPA) * Determining the Net Acid Producing Potential (NAPP) * Weight of each samples - 1 kg 2. Potential AMD analysis - classification of NAF (Non Acid Forming) and PAF (Potential Acid Forming) materials 3. AMD impacts assessment and mitigations strategies for AMDAL purpose (ANDAL, RKL and RPL). Samples were collected from the base of the weathered zone (grey shale) to at least 0.5m below the expected pit floor i.e. below the lowest seam. Samples and data required from site: * Minimum from 2 drill holes * Fresh core samples and immediately to be conservation (by "plastic warp" in order to avoid the samples direct contact with air and sunshine) in order to not oxidizing. * Number samples depending number of materials/rock types that determined based on the lithology of each drill holes. Approximately 20 samples would be taken from two drill holes (10 samples per holes). * Priority - samples taken from overburden and inter-burden based on the lithology of each drill hole sampled as follows: * Immediate roof and immediate floor or each seams include the bottom seam that will be mined * Carbonaceous clay/shale * Clay * Sand/siltstone * Weigh of each samples - 1 kg salam, SLAMET RIYADI -Original Message- From: Yan Adriansyah [mailto:[EMAIL PROTECTED] Sent: Thursday, December 22, 2005 8:02 AM To: iagi-net@iagi.or.id Subject: [iagi-net-l] AMD Issue Dear Bapak-Ibu, Barangkali ada yang bisa memberikan sharing informasi mengenai AMD, adapun informasi yang kami perlukan adalah : 1. Teknik sampling: coring atau open hole, interval, kedalaman dan jenis litologi apa yang berpotensi menjadi PAF, apakah sampling harus mencapai hingga final pit bottom elevation ?. 2. Penempatan material PAF ini dalam area dumping/disposal. 3. Kemana harus saya kirim sample ini untuk dianalisis, maklum company kami tidak memiliki lab. yang support utk pekerjaan ini seperti halnya yang ada di KPC. 4. Spasi drilling sehingga coverage area yang kita ambil sample-nya cukup memadai untuk analisis ini. Sebagai gambaran bahwa dip lapisan di area tambang kami bervariasi antara 30 - 50 degree dengan jenis litologi sandstone, mudstone dan tentunya coal. Semoga para sesepuh AMD di KPC bisa memberikan pencerahan untuk hal ini. Demikian dan terima kasih Salam YN This message and any attached files may contain information that is confidential and/or subject of legal privilege intended only for use by the intended recipient. If you are not the intended recipient or the person responsible for delivering the message to the intended recipient, be advised that you have received this message in error and that any dissemination, copying or use of this message or attachment is strictly forbidden, as is the disclosure of the information therein. If you have received this message in error please notify the sender immediately and delete the message. - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geologi : Aria A. Mulhadiono(anugraha[at]centrin.net.id) - - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI)
RE: [iagi-net-l] AMD Issue
Coba hubungi: Bapak Dr. Ir. Rudi Sayoga Gautama (AMD senior expert) Mine Environment Laboratory Mine Technique Department of ITB Jl. Ganesa 10, Bandung - 40132 Tel.: 022-2239, 250 8131 Fax.: 022 250 4209 SLAMET RIYADI -Original Message- From: Yan Adriansyah [mailto:[EMAIL PROTECTED] Sent: Thursday, December 22, 2005 4:18 PM To: iagi-net@iagi.or.id Subject: Re: [iagi-net-l] AMD Issue Pak Riyadi dan eks kolega saya di KPC, Terima kasih atas sharing informasinya, namun ada satu yang terlewat kira2 ke lab. mana sample tsb harus saya kirim ? (point pertanyaan No. 3 saya). Salam YN - Original Message - From: "Riyadi, Slamet S" <[EMAIL PROTECTED]> To: Sent: Thursday, December 22, 2005 8:46 AM Subject: RE: [iagi-net-l] AMD Issue Maksudnya Acid Mine Drainage? Walupun pertanyaan ditujukan spesifik buat orang KPC, mungkin saya bisa membantu ya? Ini saya "copy paste" saja ya? Delete--- This message and any attached files may contain information that is confidential and/or subject of legal privilege intended only for use by the intended recipient. If you are not the intended recipient or the person responsible for delivering the message to the intended recipient, be advised that you have received this message in error and that any dissemination, copying or use of this message or attachment is strictly forbidden, as is the disclosure of the information therein. If you have received this message in error please notify the sender immediately and delete the message. - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geologi : Aria A. Mulhadiono(anugraha[at]centrin.net.id) -
RE: [iagi-net-l] AMD Issue
Mas Yan, 1. Untuk menjawab pertanyaan Mas Yan sebenarnya harus dilihat dulu geologi daerah tersebut. Jadi batuan potensi PAF, metoda sampling, penempatan PAF di final dump / wetland sangat site specific artinya bisa berbeda satu site dengan site lainnya. Mungkin strategi AMD di Adaro akan berbeda dng site lain. Tetapi secara garis besar guideline akan sama. 2. Menurut saya yg pertama dilakukan adl melakukan klasifikasi batuan Adaro dengan static dan kinetic test shg bisa diketahui misalnya batuan A adl acidic dan batuan B adl benign lengkap dengan segala karakteristiknya. 3. Setelah itu ditetapkan strategi sampling dan penempatannya di final dump. 4. Strategi sampling dan penempatan waste rock juga harus melihat size bucket shovel dan mining sequence. Bila alatnya seukuran PC300 Hitachi (misalnya) berarti kemungkinan untuk 'selective mining' bisa dilakukan shg interval sampling bisa lebih rapat. 5. Strategi AMD harus dilakukan sebelum penambangan dan bukan setelah ada warna merah (acid mine drainage) muncul di discharge. Dan juga melibatkan Environment dan Mine Planning. 6. Untuk analisa static & kinetic yg lengkap dng segala interpretasinya dan strateginya, saya kira masih sedikit di Indonesia (Kecuali kalau mau bayar saya he 3x). Tetapi saya pernah dengar ada satu lab di Balikpapan yg bisa melakukan static dan kinetic test (saja) cuman saya belum konfirm ttg hal ini. 7. Maaf nggak lengkap, karena sudah lama saya tidak menyentuh isu AMD. Demikian D -Original Message- From: Yan Adriansyah [mailto:[EMAIL PROTECTED] Sent: Thursday, December 22, 2005 8:02 AM To: iagi-net@iagi.or.id Subject: [iagi-net-l] AMD Issue Dear Bapak-Ibu, Barangkali ada yang bisa memberikan sharing informasi mengenai AMD, adapun informasi yang kami perlukan adalah : 1. Teknik sampling: coring atau open hole, interval, kedalaman dan jenis litologi apa yang berpotensi menjadi PAF, apakah sampling harus mencapai hingga final pit bottom elevation ?. 2. Penempatan material PAF ini dalam area dumping/disposal. 3. Kemana harus saya kirim sample ini untuk dianalisis, maklum company kami tidak memiliki lab. yang support utk pekerjaan ini seperti halnya yang ada di KPC. 4. Spasi drilling sehingga coverage area yang kita ambil sample-nya cukup memadai untuk analisis ini. Sebagai gambaran bahwa dip lapisan di area tambang kami bervariasi antara 30 - 50 degree dengan jenis litologi sandstone, mudstone dan tentunya coal. Semoga para sesepuh AMD di KPC bisa memberikan pencerahan untuk hal ini. Demikian dan terima kasih Salam YN This message and any attached files may contain information that is confidential and/or subject of legal privilege intended only for use by the intended recipient. If you are not the intended recipient or the person responsible for delivering the message to the intended recipient, be advised that you have received this message in error and that any dissemination, copying or use of this message or attachment is strictly forbidden, as is the disclosure of the information therein. If you have received this message in error please notify the sender immediately and delete the message. - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geologi : Aria A. Mulhadiono(anugraha[at]centrin.net.id) - - To unsubscribe, send email to: iagi-net-unsubscribe[at]iagi.or.id To subscribe, send email to: iagi-net-subscribe[at]iagi.or.id Visit IAGI Website: http://iagi.or.id IAGI-net Archive 1: http://www.mail-archive.com/iagi-net%40iagi.or.id/ IAGI-net Archive 2: http://groups.yahoo.com/group/iagi Komisi Sedimentologi (FOSI) : Ratna Asharina (Ratna.Asharina[at]santos.com)-http://fosi.iagi.or.id Komisi SDM/Pendidikan : Edy Sunardi(sunardi[at]melsa.net.id) Komisi Karst : Hanang Samodra(hanang[at]grdc.dpe.go.id) Komisi Sertifikasi : M. Suryowibowo(soeryo[at]bp.com) Komisi OTODA : Ridwan Djamaluddin(ridwan[at]bppt.go.id atau [EMAIL PROTECTED]), Arif Zardi Dahlius(zardi[at]bdg.centrin.net.id) Komisi Database Geol