[WISPA] Tranzeo/Mtik disconnect issue
2nd Send How is the MT/Tranzeo Beta Firmware working? I have issues when the disconnect happens the AP shows horrible signals from the Tranzeo's (-105 to -113) but if you start a ping to that radio it drops back to -69. Is this resolved as well? If I reboot the AP all the signals are fine. I am still on the old FW. Steve Barnes RCWiFi Wireless Internet Service -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of D. Ryan Spott Sent: Tuesday, October 07, 2008 8:03 PM To: [EMAIL PROTECTED]; WISPA General List Cc: Tranzeo Support Subject: Re: [WISPA] [Tranzeo] New Update - Tranzeo/Mtik disconnect issueOct 7th, 2008 Since Damian has made this public, I guess I can talk about this testing I have been using their beta software for over 2 weeks now and I have uptimes that long as well. I will not disagree with Damian regarding the mtik patch. :) This **IS** an Mtik issue and affects more than just Tranzeo devices. ryan On Oct 7, 2008, at 2:30 PM, Damian Wallace wrote: MT has made several betas available for testing. The results are promising, but we aren't running real clients on the MT. We also have an extremely hacky way of dealing with this issue. We have an alpha available for this on a Non-Supported basis. When this feature is turned on, you have to reboot the AP when management changes like channel are made. You can get a copy of the alpha by emailing support. They will send you a copy of the firmware and a warning that this breaks a lot of ways AP send management frames, and that we don't support it. We think you are better off to use the Microtik patch since it should solve the problem for all units, not just Tranzeos. *** Register your services in our FREE WISP Locator http://www.part-15.org/maps/WISPSearch.asp *** The PART-15.ORG tranzeo Discussion List This is a Paid Subscription Email Discussion List Service. All rights reserved. All content becomes the sole property of PART-15.ORG *** To unsubscribe from the list: Send an email to: [EMAIL PROTECTED] In the Body: Unsubscribe Tranzeo WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
Re: [WISPA] Tranzeo/Mtik disconnect issue...
I would not worry about radio name not showing up. Not a single one of mine have a radio name. That is a MT thing. I wish that MT and Tranzeo would get together on that and transmit that info from the Tranzeo's. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Blair Davis Sent: Thursday, October 02, 2008 5:03 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I am starting to wounder about this issue myself Sunday, I replaced an old,(6 years in service!), Hermes I based AP, (base mounted radio, top mounted 1W amp, 150ft LMR-400) with a top mounted RB532A 5.8GHz backhaul and 2.4GHz AP. The radio card for the AP is an XR2 into a 9db Comet omni. 8ft of LMR-400. Set in B/G mode. Preamble set to both. CH9. All other settings, except ESSID are default. Connected to this AP was quite a mixture of clients, including: Tranzeo CPE-80, CPE-90, CPE-200, CPE-CPQ Lucent Hermes I client Senao CB3, EOC-2260 Ubquity NS2 Notes on the change. Sig strength reported by the mt range from -51 to -92 Thruput on the AP tripled. tests to my laptop while standing at the base exceeded 7Mb/sec which saturated my fiber. tests before the change could not exceed 2Mb/sec. The Tranzeo cpe-80 would not stay connected. it would connect and disconnect on a 5 sec cycle. replaced it with an eoc-2260 The B clients, all 6 of them, have stayed connected since power up. The NS2's, all 5 of them, seem to disconnect/reconnect in a block once or so a day. some of the remaining G clients, 4 of them, seem to disconnect/reconnect in a block in 8-9 hours the remaining G clients, 4 of them, are all over the place. from 18 hours to 1 hour. I would not read too much into this however, as some of my users power their radios down when not in use. The NS2's are all reported with anything from 1Mbps to 54Mbps as the tx rate but are always reported with 1mbps as the rx rate The NS2's are all reported with a radio name. Nothing else shows a radio name. The things I wounder about are the radio names not being reported, and the NS2's showing a 1Mbps rx rate all the time. Hope some find this useful, and any comments would be appreciated. Blair Travis Johnson wrote: This is NOT just a MT/Tranzeo issue. If you search the forums, people were talking about this issue over 6 months ago with various clients. We are running 100% MT (AP and clients) and we see the issue across ALL of our AP's. Travis Microserv D. Ryan Spott wrote: Steve and Eje, There is a bit of a forum thread here describing the issue: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Tranzeo and Mtik are working on it. On Oct 2, 2008, at 5:19 AM, Steve Barnes wrote: So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] mailto:[EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org mailto:wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units
Re: [WISPA] Tranzeo/Mtik disconnect issue...
I have determined that my Signal issues is a bad XR2. The AP gets -68 from the client and the client only gets a -81 from the AP. I have a climber going up this morning to swap it. However, I did switch 2 AP to MT and the other is working better but still drops all clients from time to time. I just Checked it and all the clients up time are exactly the same time and it would have been reset at 2:43 AM but the uptime of the MT AP is 2 days 20 min. Steve Barnes RCWiFi Wireless Internet Service -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Anthony Will Sent: Thursday, October 02, 2008 6:18 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Try pinging the NS2's with 512k or larger packets and see if they associate at a higher level. It might be showing that when there is not communication with any wi-fi device it operates in 1mb mode for basic association communication. If it changes to what you would expect then I would not be to worried about it. If it stays then be afraid... be very afraid or at least make sure you have the newest firmware on them and see if that helps. Anthony Will Broadband Corp. http://www.broadband-mn.com Blair Davis wrote: I am starting to wounder about this issue myself Sunday, I replaced an old,(6 years in service!), Hermes I based AP, (base mounted radio, top mounted 1W amp, 150ft LMR-400) with a top mounted RB532A 5.8GHz backhaul and 2.4GHz AP. The radio card for the AP is an XR2 into a 9db Comet omni. 8ft of LMR-400. Set in B/G mode. Preamble set to both. CH9. All other settings, except ESSID are default. Connected to this AP was quite a mixture of clients, including: Tranzeo CPE-80, CPE-90, CPE-200, CPE-CPQ Lucent Hermes I client Senao CB3, EOC-2260 Ubquity NS2 Notes on the change. Sig strength reported by the mt range from -51 to -92 Thruput on the AP tripled. tests to my laptop while standing at the base exceeded 7Mb/sec which saturated my fiber. tests before the change could not exceed 2Mb/sec. The Tranzeo cpe-80 would not stay connected. it would connect and disconnect on a 5 sec cycle. replaced it with an eoc-2260 The B clients, all 6 of them, have stayed connected since power up. The NS2's, all 5 of them, seem to disconnect/reconnect in a block once or so a day. some of the remaining G clients, 4 of them, seem to disconnect/reconnect in a block in 8-9 hours the remaining G clients, 4 of them, are all over the place. from 18 hours to 1 hour. I would not read too much into this however, as some of my users power their radios down when not in use. The NS2's are all reported with anything from 1Mbps to 54Mbps as the tx rate but are always reported with 1mbps as the rx rate The NS2's are all reported with a radio name. Nothing else shows a radio name. The things I wounder about are the radio names not being reported, and the NS2's showing a 1Mbps rx rate all the time. Hope some find this useful, and any comments would be appreciated. Blair Travis Johnson wrote: This is NOT just a MT/Tranzeo issue. If you search the forums, people were talking about this issue over 6 months ago with various clients. We are running 100% MT (AP and clients) and we see the issue across ALL of our AP's. Travis Microserv D. Ryan Spott wrote: Steve and Eje, There is a bit of a forum thread here describing the issue: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Tranzeo and Mtik are working on it. On Oct 2, 2008, at 5:19 AM, Steve Barnes wrote: So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone
Re: [WISPA] Tranzeo/Mtik disconnect issue...
So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
Re: [WISPA] Tranzeo/Mtik disconnect issue...
Steve and Eje, There is a bit of a forum thread here describing the issue: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Tranzeo and Mtik are working on it. On Oct 2, 2008, at 5:19 AM, Steve Barnes wrote: So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org
Re: [WISPA] Tranzeo/Mtik disconnect issue...
This is NOT just a MT/Tranzeo issue. If you search the forums, people were talking about this issue over 6 months ago with various clients. We are running 100% MT (AP and clients) and we see the issue across ALL of our AP's. Travis Microserv D. Ryan Spott wrote: Steve and Eje, There is a bit of a forum thread here describing the issue: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Tranzeo and Mtik are working on it. On Oct 2, 2008, at 5:19 AM, Steve Barnes wrote: So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: "Eje Gustafsson" [EMAIL PROTECTED] To: "'WISPA General List'" wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wire
Re: [WISPA] Tranzeo/Mtik disconnect issue...
I strongly urge everyone to send me off-list at [EMAIL PROTECTED], any suppouts videos, screen shots of this issue. I have an open case with MT. If you send it over, I will continue to gather information etc, and continue to work with MT on this issue. -- * Dennis Burgess, CCNA, A+, Mikrotik Certified Trainer Link Technologies, Inc -- Mikrotik WISP Support Services* 314-735-0270 http://www.linktechs.net http://www.linktechs.net/ */ Link Technologies, Inc is offering LIVE Mikrotik On-Line Training http://www.linktechs.net/onlinetraining.asp/* Travis Johnson wrote: This is NOT just a MT/Tranzeo issue. If you search the forums, people were talking about this issue over 6 months ago with various clients. We are running 100% MT (AP and clients) and we see the issue across ALL of our AP's. Travis Microserv D. Ryan Spott wrote: Steve and Eje, There is a bit of a forum thread here describing the issue: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Tranzeo and Mtik are working on it. On Oct 2, 2008, at 5:19 AM, Steve Barnes wrote: So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http
Re: [WISPA] Tranzeo/Mtik disconnect issue...
Sounds like the fatal flaw in this sequence would be changing back to the MT AP! ;) in jest, of course We have a couple people (that we know of) running the Cisco VPN client through our Tranzeo/StarOS combo without issue... Mark Nash UnwiredWest 78 Centennial Loop Suite E Eugene, OR 97401 541-998- 541-998-5599 fax http://www.unwiredwest.com - Original Message - From: Steve Barnes [EMAIL PROTECTED] To: WISPA General List wireless@wispa.org Sent: Thursday, October 02, 2008 5:19 AM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ -- -- WISPA Wants You! Join today! http://signup.wispa.org
Re: [WISPA] Tranzeo/Mtik disconnect issue...
I am starting to wounder about this issue myself Sunday, I replaced an old,(6 years in service!), Hermes I based AP, (base mounted radio, top mounted 1W amp, 150ft LMR-400) with a top mounted RB532A 5.8GHz backhaul and 2.4GHz AP. The radio card for the AP is an XR2 into a 9db Comet omni. 8ft of LMR-400. Set in B/G mode. Preamble set to both. CH9. All other settings, except ESSID are default. Connected to this AP was quite a mixture of clients, including: Tranzeo CPE-80, CPE-90, CPE-200, CPE-CPQ Lucent Hermes I client Senao CB3, EOC-2260 Ubquity NS2 Notes on the change. Sig strength reported by the mt range from -51 to -92 Thruput on the AP tripled. tests to my laptop while standing at the base exceeded 7Mb/sec which saturated my fiber. tests before the change could not exceed 2Mb/sec. The Tranzeo cpe-80 would not stay connected. it would connect and disconnect on a 5 sec cycle. replaced it with an eoc-2260 The B clients, all 6 of them, have stayed connected since power up. The NS2's, all 5 of them, seem to disconnect/reconnect in a block once or so a day. some of the remaining G clients, 4 of them, seem to disconnect/reconnect in a block in 8-9 hours the remaining G clients, 4 of them, are all over the place. from 18 hours to 1 hour. I would not read too much into this however, as some of my users power their radios down when not in use. The NS2's are all reported with anything from 1Mbps to 54Mbps as the tx rate but are always reported with 1mbps as the rx rate The NS2's are all reported with a radio name. Nothing else shows a radio name. The things I wounder about are the radio names not being reported, and the NS2's showing a 1Mbps rx rate all the time. Hope some find this useful, and any comments would be appreciated. Blair Travis Johnson wrote: This is NOT just a MT/Tranzeo issue. If you search the forums, people were talking about this issue over 6 months ago with various clients. We are running 100% MT (AP and clients) and we see the issue across ALL of our AP's. Travis Microserv D. Ryan Spott wrote: Steve and Eje, There is a bit of a forum thread here describing the issue: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Tranzeo and Mtik are working on it. On Oct 2, 2008, at 5:19 AM, Steve Barnes wrote: So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: "Eje Gustafsson" [EMAIL PROTECTED] To: "'WISPA General List'" wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that
Re: [WISPA] Tranzeo/Mtik disconnect issue...
Try pinging the NS2's with 512k or larger packets and see if they associate at a higher level. It might be showing that when there is not communication with any wi-fi device it operates in 1mb mode for basic association communication. If it changes to what you would expect then I would not be to worried about it. If it stays then be afraid... be very afraid or at least make sure you have the newest firmware on them and see if that helps. Anthony Will Broadband Corp. http://www.broadband-mn.com Blair Davis wrote: I am starting to wounder about this issue myself Sunday, I replaced an old,(6 years in service!), Hermes I based AP, (base mounted radio, top mounted 1W amp, 150ft LMR-400) with a top mounted RB532A 5.8GHz backhaul and 2.4GHz AP. The radio card for the AP is an XR2 into a 9db Comet omni. 8ft of LMR-400. Set in B/G mode. Preamble set to both. CH9. All other settings, except ESSID are default. Connected to this AP was quite a mixture of clients, including: Tranzeo CPE-80, CPE-90, CPE-200, CPE-CPQ Lucent Hermes I client Senao CB3, EOC-2260 Ubquity NS2 Notes on the change. Sig strength reported by the mt range from -51 to -92 Thruput on the AP tripled. tests to my laptop while standing at the base exceeded 7Mb/sec which saturated my fiber. tests before the change could not exceed 2Mb/sec. The Tranzeo cpe-80 would not stay connected. it would connect and disconnect on a 5 sec cycle. replaced it with an eoc-2260 The B clients, all 6 of them, have stayed connected since power up. The NS2's, all 5 of them, seem to disconnect/reconnect in a block once or so a day. some of the remaining G clients, 4 of them, seem to disconnect/reconnect in a block in 8-9 hours the remaining G clients, 4 of them, are all over the place. from 18 hours to 1 hour. I would not read too much into this however, as some of my users power their radios down when not in use. The NS2's are all reported with anything from 1Mbps to 54Mbps as the tx rate but are always reported with 1mbps as the rx rate The NS2's are all reported with a radio name. Nothing else shows a radio name. The things I wounder about are the radio names not being reported, and the NS2's showing a 1Mbps rx rate all the time. Hope some find this useful, and any comments would be appreciated. Blair Travis Johnson wrote: This is NOT just a MT/Tranzeo issue. If you search the forums, people were talking about this issue over 6 months ago with various clients. We are running 100% MT (AP and clients) and we see the issue across ALL of our AP's. Travis Microserv D. Ryan Spott wrote: Steve and Eje, There is a bit of a forum thread here describing the issue: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Tranzeo and Mtik are working on it. On Oct 2, 2008, at 5:19 AM, Steve Barnes wrote: So let me get this right. If you have Tranzeo CPE's you only use StarOS. MT does not work. Does Mikrotik even acknowledge that this is a issue and do they have plans to fix it. Part of the issue is I could not make Cisco VPN's work with StarOS V3 AP and a Tranzeo CPE. Had to change to a StarOS CPE. Now I changed to the MT AP and the StarOS CPE didn't work right. So I changed the CPE back to a Tranzeo, VPN's work great now but the Tower reboots. ARG! Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Nash Sent: Wednesday, October 01, 2008 9:50 PM To: WISPA General List Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA
[WISPA] Tranzeo/Mtik disconnect issue...
I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
Re: [WISPA] Tranzeo/Mtik disconnect issue...
Steve, Tranzeo and Mtik are working on this: http://forum.mikrotik.com/viewtopic.php?f=7t=24971 Feel free to comment on this post or email support referencing the ticket number shown in the forum post. I can't say too much but I can say that both parties are _actively_ working on the issue. ryan On Oct 1, 2008, at 1:20 PM, Steve Barnes wrote: I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
Re: [WISPA] Tranzeo/Mtik disconnect issue...
You better switch that AP back to StarOS before you start loosing customers. Mine started to get pretty irate after about 2 weeks. There is nothing you can do to stop it or slow it down either. Kurt Fankhauser WAVELINC P.O. Box 126 Bucyrus, OH 44820 419-562-6405 www.wavelinc.com -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 4:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
Re: [WISPA] Tranzeo/Mtik disconnect issue...
We're migrating EVERYTHING to StarOS. I've got 150 or so Tranzeo TR-CPQ's in the field associated with StarOS APs, not experiencing a problem. - Original Message - From: Kurt Fankhauser [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 3:58 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... You better switch that AP back to StarOS before you start loosing customers. Mine started to get pretty irate after about 2 weeks. There is nothing you can do to stop it or slow it down either. Kurt Fankhauser WAVELINC P.O. Box 126 Bucyrus, OH 44820 419-562-6405 www.wavelinc.com -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 4:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
Re: [WISPA] Tranzeo/Mtik disconnect issue...
Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
Re: [WISPA] Tranzeo/Mtik disconnect issue...
I do wish the Tranzeos had a ping watchdog feature... - Original Message - From: Eje Gustafsson [EMAIL PROTECTED] To: 'WISPA General List' wireless@wispa.org Sent: Wednesday, October 01, 2008 6:27 PM Subject: Re: [WISPA] Tranzeo/Mtik disconnect issue... Odd behavior. This must be a mismatch in the protocol between the Tranzeo units and MikroTik. We have tested many different units (E-zy.net, Senao/Engenius, MikroTik, Ubiquiti as well Teletronics) and never seen this behavior you describe. However I do recall way back someone had very strange behaviors going on between Tranzeo units and his MikroTik AP. He had some Senao CB3 units and some Smartbridges that he swapped some of the Tranzeo units with and the problems with those clients went away. Not sure what the Tranzeo units are or are not doing when communicating with the MikroTik AP thought this been long since fixed but if it was the problem seems to once again surfaced. / Eje -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Barnes Sent: Wednesday, October 01, 2008 3:20 PM To: WISPA General List Cc: Scott Reed; Blake King; Rick Harnish Subject: [WISPA] Tranzeo/Mtik disconnect issue... I am wondering about a resolution on this. I had a failing StarOS Board so I switched out to a Mikotik RB411 v3.10. Now all 45 of my clients (all are Tranzeo) reset every few minutes. Normally 5min. I have also noticed that at times the signal Strength on my clients go super high like a client at -68 will be at -98. However, if I ping that client they drop back to the -68. As soon as you stop the Ping the signal strength on the AP goes back to -99. If I reboot the Radio it sets everyone back to Really good signal strength for a while then it starts to climb. I had no one over -80 on the star board. I just had 12 clients the MT said was at -112 to -116. Ping them and during the ping they are back to -68. Help. I will be a guinea pig if someone wants to look at my tower from MT. it can't get much Worse. Steve Barnes Executive Manager PCS-WIN RCWiFi Wireless Internet Service (765)584-2288 WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/
[WISPA] Tranzeo/Mtik disconnect issue...
Does anyone have a Tranzeo or a Mikrotik ticket number I can reference when I open a ticket? Travis? Marlon? http://forum.mikrotik.com/viewtopic.php?f=7t=24971p=127269 ryan WISPA Wants You! Join today! http://signup.wispa.org/ WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/