Re: [OSL | CCIE_Voice] Barge is not working in SRST - RESOLVED

2011-01-18 Thread Mritunjay Kumar
Hi Shrini, Thanks for your time on this issue. but i am still wondering , how my config is different than yours. I disabled privacy under telephony service as well as under both ephones but still did not work for me. Please clarify further. appreciate your help ! Regards, Mritunjay On Wed, Jan

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-18 Thread Mark Holloway
our >> public website at www.ipexpert.com <http://www.ipexpert.com/> >> >> From: Mritunjay Kumar >> Date: Tue, 18 Jan 2011 15:49:00 +0530 >> To: Miron Kobelski , Shrini >> Cc: OSL Group >> Subject: Re: [OSL | CCIE_Voice] Barge is not

Re: [OSL | CCIE_Voice] Barge is not working in SRST - RESOLVED

2011-01-18 Thread Shrini
Hi Mrintunjay, Here is the working config. Took an hour to figure it out :-) There is a bug associated with CME 12.4T /CSCti11843/ telephony-service sdspfarm units 2 sdspfarm tag 1 BR1-CNF no privacy conference hardware srst mode auto-provision none srst ephone template 1 srst dn line-mod

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-18 Thread Amit Batra
rt.com/> From: Mritunjay Kumar Date: Tue, 18 Jan 2011 15:49:00 +0530 To: Miron Kobelski , Shrini Cc: OSL Group Subject: Re: [OSL | CCIE_Voice] Barge is not working in SRST Hi Shrini, http://onlinestudylist.com/archives/ccie_voice/2010-November/071295.html "privacy off" under e

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-18 Thread Vik Malhi
Mritunjay Kumar Date: Tue, 18 Jan 2011 15:49:00 +0530 To: Miron Kobelski , Shrini Cc: OSL Group Subject: Re: [OSL | CCIE_Voice] Barge is not working in SRST Hi Shrini, http://onlinestudylist.com/archives/ccie_voice/2010-November/071295.html "privacy off" under ephone-template

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-18 Thread Mritunjay Kumar
Hi Shrini, http://onlinestudylist.com/archives/ccie_voice/2010-November/071295.html "privacy off" under ephone-template does not work as this is a bug. it is tested and discussed at http://onlinestudylist.com/archives/ccie_voice/2010-November/071295.html but i tried with ephone template but

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-18 Thread Miron Kobelski
Hi, I suggest to follow Randall's suggestion, as this has already been discussed many times... regards kobel On Mon, Jan 17, 2011 at 11:35, Mritunjay Kumar wrote: > Hi All, > > thanks for reply and sorry for delayed response. > > set the max-ephone to 2 and phone type is set but still not wor

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-18 Thread Shrini
_ From: Mritunjay Kumar [mailto:mjs...@gmail.com] Sent: Tuesday, January 18, 2011 12:27 AM To: Shrini Cc: Randall Saborio; ccie_voice@onlinestudylist.com Subject: Re: [OSL | CCIE_Voice] Barge is not working in SRST Hi Shrini, created the mentioned ephone-dn ..did not help. Phones are

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-18 Thread Mritunjay Kumar
onday, January 17, 2011 2:35 AM > *To:* Randall Saborio > > *Cc:* ccie_voice@onlinestudylist.com > *Subject:* Re: [OSL | CCIE_Voice] Barge is not working in SRST > > Hi All, > > thanks for reply and sorry for delayed response. > > set the max-ephone to 2 and phone type is set but

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-17 Thread Shrini
2:35 AM To: Randall Saborio Cc: ccie_voice@onlinestudylist.com Subject: Re: [OSL | CCIE_Voice] Barge is not working in SRST Hi All, thanks for reply and sorry for delayed response. set the max-ephone to 2 and phone type is set but still not working :( is octo number shared by two phone which i

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-17 Thread Mritunjay Kumar
Hi All, thanks for reply and sorry for delayed response. set the max-ephone to 2 and phone type is set but still not working :( is octo number shared by two phone which is used for Cbarge is adhoc conference number. Is there any bug or workaround. same config was working earlier! R

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-16 Thread Shrini
com [mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Bo Gao Sent: Sunday, January 16, 2011 11:55 AM To: Mritunjay Kumar Cc: ccie_voice@onlinestudylist.com Subject: Re: [OSL | CCIE_Voice] Barge is not working in SRST Try set your phone type under ephone. Bo On Sun, Jan 16, 2011 at 4:26

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-16 Thread Bo Gao
Try set your phone type under ephone. Bo On Sun, Jan 16, 2011 at 4:26 AM, Mritunjay Kumar wrote: > Hi All , > > Cbarge in SRST is not working > > here is the config > > telephony-service > sdspfarm units 2 > sdspfarm tag 1 BR1-CNF > no privacy > conference hardware > srst mode auto-provi

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-16 Thread natan 2me
hi. since u are doing srst 'none' and u have 20 ephones and ephone1/2 preconf - did u check your actual phones are registering with the ephone1/2? So, that they get the privacy off? Go with max-ephones 2 Natan On Sun, Jan 16, 2011 at 5:25 PM, Randall Saborio wrote: > This problem has come up qu

Re: [OSL | CCIE_Voice] Barge is not working in SRST

2011-01-16 Thread Randall Saborio
This problem has come up quite a few times on this mailing list. You can go to the archives and do a search and you should find the solution: http://onlinestudylist.com/archives/ccie_voice/ On Sun, Jan 16, 2011 at 6:26 AM, Mritunjay Kumar wrote: > Hi All , > > Cbarge in SRST is not working > >

[OSL | CCIE_Voice] Barge is not working in SRST

2011-01-16 Thread Mritunjay Kumar
Hi All , Cbarge in SRST is not working here is the config telephony-service sdspfarm units 2 sdspfarm tag 1 BR1-CNF no privacy conference hardware srst mode auto-provision none srst dn line-mode dual max-ephones 20 max-dn 20 ip source-address 14.160.116.40 port 2000 max-conferences 12