Dear all,
I just learned that the attached PDF was not passed to the BB.
Here is the add.
Best,
Xavier
*4 PhD student positions available at the Structural Biology Department of
IBMB-CSIC*. *Unit of Excellence “María de Maeztu**”*
The “María de Maeztu” Structural Biology Unit of IBMB-CSIC
Dear all,
The Diamond Light Source Macromolecular Crystallography group would like to
invite both our academic and industrial users to MX beamline training sessions
on the 15th -16th July 2015.
The aim is to provide MX users with sufficient training to be able to operate
any of the Diamond MX
PhD fellowship in crystallography of G protein-coupled receptors
The Department of Drug Design and Pharmacology, Faculty of Health and Medical
Sciences, University of Copenhagen is pleased to announce that a PhD fellowship
will be available from Oct 1st 2105 or soon thereafter in discussion
Dear Dusan,
Following up on Gerard's comment, we also read your nice paper with great
interest. Your method appears most useful for cases with a limited number of
reflections (e.g., small unit cell and/or low resolution) resulting in 5% test
sets with less than 1000 reflections in total. It
PhD position in Computational Biophysics
Topic: Molecular dynamics simulations of X-ray scattering experiments
A PhD position is available in the group of Dr. Jochen Hub at the
Georg-August-University Göttingen, Germany. The application deadline is
July 5, 2015.
For more details, please visit
Hi Fellows,
thanks again to all who took the time to respond (often very
extensively) to my queries regarding funding experience and resource
distribution. The summary is available now ahead of print:
http://www.ncbi.nlm.nih.gov/pubmed/26051321
Let's hope it has some positive
I think the Zalman's are not available anymore. When our last one died we
bought the Asus VG23AH (also passive 3D). Works similar to the Zalman for
Coot and Pymol,
Best,
Daniel
On Wed, Jun 10, 2015 at 5:00 AM, Peng GONG
055a9db99734-dmarc-requ...@jiscmail.ac.uk wrote:
Hi Tom,
I think any
Dear all,
MoRDa is a pipeline for molecular replacement protein structure
solution with X-ray data. MoRDa is based upon its own domain database.
The software package contains a database and a set of programs
for structure solution.
The package is available for Mac or Linux.
You can find more
It works again now. Sorry for the inconvenience.
--Gerard
On Tue, 9 Jun 2015, Xiao Lei wrote:
Hi All,
I am trying to get electron density map of some pdb structures, I know
there is a database called Electron density server (EDS
http://eds.bmc.uu.se/eds). But somehow these days I can not
hi
If you pre-process the images with the Bruker utility frm2frm* you should be
able to transform them into a format that Mosflm can process.
* it used to be called frm2frm, but may now be called something else - someone
from Bruker should be able to help you!
Harry
--
Dr Harry Powell, MRC
Dear All, We havecollected the data from a Bruker x-ray machine, it was in
.sfrm format which isnot readable by mosflm and hkl2000. Can you people help me
how to workout this problemby mosflm or any other suitable software .
Thanks in advance
Hi Harry,
We have tried the frm2frm sofware but it didn't work out for as.
On Wednesday, 10 June 2015 12:54 PM, Harry Powell
ha...@mrc-lmb.cam.ac.uk wrote:
hi
If you pre-process the images with the Bruker utility frm2frm* you should be
able to transform them into a format that
Tarun,
in my group we used to have a Proteum6000 CCD from Bruker. With the right
detector descriptions from the HKL folks we able to use HKL2000, talk to the
hkl folks, you may also need another license covering that detector though.
Alternatively Bruker provides the Proteum suite (I think that
Your Figure 1 suggest a secret message - or at least I view it that way.
The early steps “basic research” seems to be funded by Euros, while the in
silico part is funded in Dollars.
Or was that unintentional ?
Jürgen
..
Jürgen Bosch
Johns Hopkins University
Bloomberg School
I would like to draw your attention to a postdoctoral position in Amgen San
Francisco. Please apply through the following link.
http://careers.amgen.com/en/jobs/descriptions/postdoctoral-fellow-molecular-engineering-south-san-francisco-job-5461195
Xiaoshan Min
Molecular Structure
Amgen San
Hi Tarun,
Carsten is right the Proteum2 software is really good. I can send you
some introduction pdfs and for SADABS (scaling) I am currently writing
an SOP, the manual is also well written.
Besides this the program to unwarp and convert images, is in the
instrument tab.
Best regards,
I don't think the .sfrm ending means that the data can or can not be read by
non-Bruker software.
The crucial difference is between warped and unwarped data, if I understand
correctly. XDS (and I think MOSFLM) can only process unwarped data. As Harry
says, there is an unwarping utility from
of course, Kay is right; I just assumed that the frames were warped, or not
corrected for spatial distortion. Mosflm does require unwarped data from the
Bruker CCD detectors. I haven't seen images from their CMOS detectors which may
not require unwarping (but probably will...).
Harry
--
Dr
On Wednesday, 10 June, 2015 17:35:25 Mengbin Chen wrote:
Hello everyone,
I am refining a 2.5 angstrom structure whose phase is solved by molecular
replacement with a search probe determined by SAD with 3 angstrom
resolution. While I am able to see densities of a bunch of water molecules
and
Hello everyone,
I am refining a 2.5 angstrom structure whose phase is solved by molecular
replacement with a search probe determined by SAD with 3 angstrom
resolution. While I am able to see densities of a bunch of water molecules
and ligands in the MR solved structure, which means that the phase
Thank you Jacob and Ethan!
I haven't put water molecules into the density blob, which aren't many out
there, but I fitted the ligands in already. Molbrobity statistics are not
yet great, since there are 13.5% rotamer outliers.
Will adjust the models manually, and try refmac and TLS refinement.
Dear Carsten, dear Tarun
are you sure HKL can process the unwarped images? As far as I
understand, the distortion is detector specific, i.e. each detector has
its own undistortion description. As Kay pointed out, reading sfrm is
not a problem, it is very well documented (and a neat format).
Once
22 matches
Mail list logo