Can a 3104 serial interface provide clocking? [7:1656]

2001-04-23 Thread Nathan Cruz
I am trying to hook up two 3104's back to back but when I try to put in clock 64000 I get the error msg. "Not allowed on DTE interface". When in fact the sh controller command shows that it is a dce cable attached. Any help would be appreciated. Thanks. Nathan Message Posted at: http://www.gr

Re: Can a 3104 serial interface provide clocking? [7:1656]

2001-04-23 Thread Kevin Wigle
s here can concoct a special cable for you???) Kevin Wigle - Original Message - From: "Nathan Cruz" To: Sent: Monday, 23 April, 2001 19:19 Subject: Can a 3104 serial interface provide clocking? [7:1656] > I am trying to hook up two 3104's back to back but when I try to pu

Re: Can a 3104 serial interface provide clocking? [7:1656]

2001-04-23 Thread Circusnuts
s you the speeds available) works better than using clockrate. Let us know how you make out. I have 5 of these routers & have upgraded probably 25 or 30 of them. Phil - Original Message - From: Nathan Cruz To: Sent: Monday, April 23, 2001 7:19 PM Subject: Can a 3104 serial inter

Re: Can a 3104 serial interface provide clocking? [7:1656]

2001-04-23 Thread Kevin Wigle
I stand corrected - that's what I have.. a 3102 - Original Message - From: "Circusnuts" To: "Kevin Wigle" ; Sent: Monday, 23 April, 2001 20:39 Subject: Re: Can a 3104 serial interface provide clocking? [7:1656] > 3104's & 3204's o

Re: Can a 3104 serial interface provide clocking? [7:1656]

2001-04-23 Thread Circusnuts
3104's & 3204's operate both DCE & DTE. 3102's & 3202 only operate as DTE. Most all V2 interfaces have DCE available. Phil - Original Message - From: Kevin Wigle To: Sent: Monday, April 23, 2001 7:40 PM Subject: Re: Can a 3104 serial interface provide