Re: Catalyst 2950 CRC Errors [7:51419]

2002-08-16 Thread Marty Adkins
John Neiberger wrote: We've had nothing but bad luck with the 3C905C NICs. We've purchased a *bunch* of low-end Dell PCs that have that NIC and they tend to get the blue screen of death and then reboot if they're connected to Cisco switches, especially when STP is turned on. Very odd

Re: Catalyst 2950 CRC Errors [7:51419]

2002-08-16 Thread Dain Deutschman
: [EMAIL PROTECTED] Subject: Re: Catalyst 2950 CRC Errors [7:51419] Also...I have tested the wiring(basic tester...no NEXT/FEXT or other factors...but lengths of cable are under 50ft) and replaced patch cables...still no luck. Dain. Dain Deutschman wrote in message [EMAIL PROTECTED]"

Re: Catalyst 2950 CRC Errors [7:51419]

2002-08-15 Thread John Neiberger
We've had nothing but bad luck with the 3C905C NICs. We've purchased a *bunch* of low-end Dell PCs that have that NIC and they tend to get the blue screen of death and then reboot if they're connected to Cisco switches, especially when STP is turned on. Very odd behavior and we haven't found a

Catalyst 2950 CRC Errors [7:51419]

2002-08-14 Thread Dain Deutschman
Hello Everyone, I have a Cat2950 in a small office throwing up thousands of CRCs, input errors and several runts on the port connected to the server. Clients are getting disconnected and database on server is constantly having to be repaired. The errors always follow the server no matter which

Re: Catalyst 2950 CRC Errors [7:51419]

2002-08-14 Thread Dain Deutschman
Also...I have tested the wiring(basic tester...no NEXT/FEXT or other factors...but lengths of cable are under 50ft) and replaced patch cables...still no luck. Dain. Dain Deutschman wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... Hello Everyone, I have a Cat2950 in a small