NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-28 Thread Jablonski, Michael
Has anyone had any experience w/the following combination? 3640 & NM-1HSSI & Kentrox DataSMART T3/E3 IDSU I've been trying, to no avail, to bring the HSSI up for a 12M DS3 The CSU/DSU, according to the lights, is ready to send and receive data; but when I bring up the int on the router, it s

Re: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-28 Thread Ishrat Zahid
Don't you need clock on serials? /Nadeem Jablonski, Michael wrote: >Has anyone had any experience w/the following combination? > >3640 & NM-1HSSI & Kentrox DataSMART T3/E3 IDSU > >I've been trying, to no avail, to bring the HSSI up for a 12M DS3 The >CSU/DSU, according to the lights, is rea

RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-29 Thread [EMAIL PROTECTED]
What does the physical layer say? sh controller (intf) Martijn -Oorspronkelijk bericht- Van: Jablonski, Michael [mailto:[EMAIL PROTECTED] Verzonden: dinsdag 29 juli 2003 0:24 Aan: [EMAIL PROTECTED] Onderwerp: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129] Has anyone had any experience

Re: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-29 Thread MADMAN
FWIW, here is a current working config, 3640 to a Kentrox. If you have the cable connected and the CSU powered you should get an up/down state. interface Hssi3/0 description to Qwest x ip address x.x.x.x 255.255.255.252 encapsulation ppp load-interval 30 serial restart-delay 0

Re: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-29 Thread John Neiberger
Mike, I'd try replacing the cable first if you have one available. Even if the DS3 isn't configured correctly your interface should be up if you're router is speaking to your IDSU. I'd also try resetting the IDSU to its defaults just to make sure something in the config on the IDSU isn't breaking

RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-29 Thread Joel Satterley
PROTECTED] Subject: Re: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129] Mike, I'd try replacing the cable first if you have one available. Even if the DS3 isn't configured correctly your interface should be up if you're router is speaking to your IDSU. I'd also try resetting the

RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-29 Thread s vermill
Jablonski, Michael wrote: > > Has anyone had any experience w/the following combination? > > 3640 & NM-1HSSI & Kentrox DataSMART T3/E3 IDSU > > I've been trying, to no avail, to bring the HSSI up for a 12M > DS3 The > CSU/DSU, according to the lights, is ready to send and receive > data; bu

RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-30 Thread Jablonski, Michael
ECTED] Subject: RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129] Jablonski, Michael wrote: > > Has anyone had any experience w/the following combination? > > 3640 & NM-1HSSI & Kentrox DataSMART T3/E3 IDSU > > I've been trying, to no avail, to bring the HSSI up fo

RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129]

2003-07-30 Thread Jablonski, Michael
2003 8:56 AM To: [EMAIL PROTECTED] Subject: RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129] Yeah it's a HSSI cable... CAB-HSI1 is the part. Telco is using the default HDLC for encapsulation. I've got telco coming out today to test the line. According to Kentrox's doc, a T3 w/H

RE: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129] (2) [7:73145]

2003-07-29 Thread [EMAIL PROTECTED]
Levering *070 - 44 12285 * [EMAIL PROTECTED] -Oorspronkelijk bericht- Van: Jablonski, Michael [mailto:[EMAIL PROTECTED] Verzonden: dinsdag 29 juli 2003 0:24 Aan: [EMAIL PROTECTED] Onderwerp: NM-1HSSI w/kentrox DataSMART T3/E3 [7:73129] Has anyone had any experience w/the following