Re: Frame-Relay Problem [7:41250]

2002-04-13 Thread Michael Williams
Sean brings up a good point to check the maximum clock rate of your module. I've seen more than 1 person try to use the A/S module for 1.544Mbps However, the A/S module that he refers to supports a max of 115.2Kbps in async mode and when put into sync mode supports a max of 128Kbps. This

Re: Frame-Relay Problem [7:41250]

2002-04-12 Thread PING
on the interface) * Issue a no shut on all frame-relay interfaces on both ends of the PVC. hth, Sean -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of PING Sent: Thursday, April 11, 2002 7:43 PM To: [EMAIL PROTECTED] Subject: Re: Frame-Relay Problem [7

Re: Frame-Relay Problem [7:41250]

2002-04-11 Thread Chris Camplejohn
Did you put frame-relay intf-type on the frame-interface? Chris PING wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... If I have this simple net: 3660(FR Switch)---3640 I am using NM-4T on both routers. Default (HDLC) encapsulation causes both router serial

RE: Frame-Relay Problem [7:41250]

2002-04-11 Thread Lupi, Guy
Do you have another router to connect to the 3660? This would give you a better idea of how it really works. It looks like right now you are trying to do frame relay back to back, which also works, but it depends on how you have your settings. If you want to do frame relay encapsulation back

Re: Frame-Relay Problem [7:41250]

2002-04-11 Thread Engelhard M. Labiro
Ping, Have you configure the following comands on FR switch ? 1. Global config mode : frame-relay switching 2. Interface config mode: frame-relay intf-type dce - Original Message - From: PING To: Sent: Friday, April 12, 2002 10:49 AM Subject: Frame-Relay Problem [7:41250] If I

Re: Frame-Relay Problem [7:41250]

2002-04-11 Thread PING
Yes. It works from 3660 to 3800. Doesn't work from NM-4T to NM-4T. /N Chris Camplejohn wrote: Did you put frame-relay intf-type on the frame-interface? Chris PING wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... If I have this simple net: 3660(FR

Re: Frame-Relay Problem [7:41250]

2002-04-11 Thread PING
The question is that Caslow says on page-110 that if FR switching is on, just enabling the encapsulation will bring up the PVC by using inverse arp. I don't see that happening. /N Engelhard M. Labiro wrote: Ping, Have you configure the following comands on FR switch ? 1. Global config mode

RE: Frame-Relay Problem [7:41250]

2002-04-11 Thread Sean Knox
]]On Behalf Of PING Sent: Thursday, April 11, 2002 7:43 PM To: [EMAIL PROTECTED] Subject: Re: Frame-Relay Problem [7:41250] The question is that Caslow says on page-110 that if FR switching is on, just enabling the encapsulation will bring up the PVC by using inverse arp. I don't see that happening. /N