RE: Frame-relay HSRP [7:72166]

2003-07-13 Thread mccloud mike
I have seen this problem before with frame. LMI being local to the frame switch means the interface does not go down and backups routes do not kick in. One way to overcome this is to monitor layer 2 by using the #8220;frame-relay end-to-end keepalive mode bidirectional#8221; command within a map

RE: Frame-relay HSRP [7:72166]

2003-07-13 Thread Salvatore De Luca
Ahh yes.. you can do this also.. pending you have 12.0(5)T or later. The only issue with that is you might want to modify the frame-relay end-to-end keepalive timer As you stated, Within the 15 second intervals x3 you are looking at a good 45 seconds before the WAN interface goes down down ,plus

RE: Frame-relay HSRP [7:72166]

2003-07-11 Thread Salvatore De Luca
When you have a FR connection, you have a dedicated circuit to your provider which then on taps into the frame cloud. So consider it alomost like a point-to-point link to your local Carrier and then from there you connect within the providers Frame Switch into their Frame Relay cloud. Now, when