RE: Frame Relay Question [7:31210]

2002-01-08 Thread Patrick Ramsey
what's the unused column? -Patrick Scott Nawalaniec 01/07/02 05:10PM Hi Matt, You are correct...The DLCI is being learned from the frame-relay switch...You don't have it configured so it will show up under the unused column when the sho fram pvc command. Did you order the pvc and haven't

RE: Frame Relay Question [7:31210]

2002-01-07 Thread Scott Nawalaniec
Hi Matt, You are correct...The DLCI is being learned from the frame-relay switch...You don't have it configured so it will show up under the unused column when the sho fram pvc command. Did you order the pvc and haven't configured it or assigned it to an interface/sub-interface? Or the provider

Re: Frame Relay Question [7:31210]

2002-01-07 Thread MADMAN
Yes it definately could have been learned from the provider or you had it configured on your router at some point and later took it out of your config. It the second case is true a reload will get rid of it. Does it claim to be learned dynamically?? Dave matt wrote: So...I am looking at

Re: Frame Relay Question [7:31210]

2002-01-07 Thread matt