Re: [Elecraft] K3 no power out

2023-02-15 Thread Matthew Cook
Josep, After the basic checks that Dave and Fred have suggested, if you've not seen any life I'd quickly check what happens if you turn the power down to under 10W, this will bypass the KPA3 and if you still see no output then the problem is deeper into the radio. From here I'd talk to the folks

Re: [Elecraft] K3 no power out

2023-02-14 Thread Ed Cole
A couple days ago I encountered that kind of issue: I had the K3 in DATA mode "looking at the psk-31 mode" and went to shift back to USB, but the XMIT/TUNE button yielded no output. Checked thru the list you provided and checked that I was in ANT1 output as I have run xvtr mode in the past.

Re: [Elecraft] K3 no power out

2023-02-09 Thread Fred Jensen
Right on Dave, except that "simple" is a better term than "obvious."  My K3 is S/N 642 ... very long in the tooth now.  Perhaps 8 or 9 years ago 30 m quit.  Just internal noise and infinite SWR.  All the other bands were fine.  After about 2 days of fooling with the myriad of connectors and cab

Re: [Elecraft] K3 no power out

2023-02-09 Thread Dave New, N8SBE
Josep, Please check the obvious things: 1) Is 'test mode' on? 2) Is the power level turned to zero? 3) Is the VOX on (for CW)? 4) Are you using the right antenna selection? 5) Is your key plugged in/wiring OK? I know some of this is really basic, but sometimes in the heat of battle, something

[Elecraft] K3 no power out

2023-02-08 Thread Josep Torres via Elecraft
Hi all, Bad news here…. My K3 (radio 1) is not transmitting power out.!! I have used this morning as I normally do and all was fine. Around 1330h local time, I turned it on again and did QSO with CT7/DJ2PR and all was fine. I let the radio on as the CWT contest started at 1400h local. When I s

Re: [Elecraft] k3 no power out over 12 watts

2022-05-06 Thread Michael Carter
Hi Scott, Check the KPA3 settings in the CONFIG menu to be sure the 100 watt PA is not bypassed. If the KPA3 is set to PA NOR in the CONFIG menu, then you may have a diode failure in the PIN diode T/R switch or the PA bypass PIN diode switch. Mike, K8CN

[Elecraft] k3 no power out over 12 watts

2022-05-06 Thread NE9U - Scott Jasper
Turned on my k3 couple days ago and I suddenly have no power out over 12 watts.  Had been working fine prior to that.?? Tried running the power calibration routine.  5 watts calibration worked.  50 watts erred out. rig is not in test mode. any hints on anything to check? -- Scot

[Elecraft] K3 No Power out 2M

2020-12-04 Thread Ronnie Hull
I recently got my K3 back from Elecraft after having an alignment and total checkout and some hardware upgrades I have the 2M module installed. When attempting to use it yesterday on 2M FM and it’s only putting out 100mw’s!!! Anyone know of a setting that needs to be checked? I hate to call Elec

Re: [Elecraft] K3 No power out

2018-08-18 Thread Bob Wilson, N6TV
From the "Troubleshooting" section of the K3 manual: *No power output*: You may have routed RF through the KXV3’s XVTR IN/OUT jacks, either by switching to a transverter band, or by setting CONFIG:KXV3 to TEST. Also try redoing TX GAIN cal (pg. 49). 73, Bob, N6TV On Tue, Aug 14, 2018 at 9:29 PM,

Re: [Elecraft] K3 No power out

2018-08-15 Thread Nr4c
“Test” mode wouldn’t survive a power cycle I don’t believe. Sent from my iPhone ...nr4c. bill > On Aug 15, 2018, at 7:25 AM, David Bunte wrote: > > Don - > > If this was suggested before, I missed it and apologize for the redundancy. > Has the rig inadvertently been put into the test mode? I

Re: [Elecraft] K3 No power out

2018-08-15 Thread David Bunte
Don - If this was suggested before, I missed it and apologize for the redundancy. Has the rig inadvertently been put into the test mode? If the TX indicator under the VFO A box is blinking, that would explain the symptoms. Dave - K9FN On Wed, Aug 15, 2018 at 12:30 AM Don Roberts via Elecraft < e

Re: [Elecraft] K3 No power out

2018-08-15 Thread Jim Blanca
Don, Have you tried transmitting at 10 watts, and do you get RF output? Do you also loose receive when you pass the 12 watt threshold? If you have any of these symptoms, good chance it’s a PIN T/R malfunction. My beloved K3 was doing the same thing... one day she was running like a champ, next da

[Elecraft] K3 No power out

2018-08-14 Thread Don Roberts via Elecraft
Yes I can set it at 35 watts which is what I usually use to drive the KPA 500, and speak in the mic for ssb and get no power out. In cw at the same 35 watts, when I send code either straight key or padfle. 0 watts out. Same results if I attempt to run bearfoot at 100 watts or 5 watts, I get no p

Re: [Elecraft] K3 No power out

2018-08-14 Thread Mike Flowers
Elecraft service set my Tune Pwr to 5.1 watts to prevent ‘inadvertent running of TX gain calibration’. Have you tried running the TX gain calibration with the K3 Utility? -- Mike Flowers, K6MKF, NCDXC - "It's about DX!" > On Aug 14, 2018, at 5:31 PM, Dennis Moore wrote: > > "No power to tune

Re: [Elecraft] K3 No power out

2018-08-14 Thread Dennis Moore
"No power to tune anything." Does this mean you've only tried to tune, and haven't tried actually transmitting cw or phone? If so, and I don't know how it would have changed, have you checked the Menu-Config-TUN PWR to see what it is set to? If it is set to .1 it will show 0.0 73, Dennis NJ6G

[Elecraft] K3 No power out

2018-08-14 Thread Don Roberts via Elecraft
I have enjoyed the wisdom of this group and have learned so much but now it is my time to ask for help. My K3 is showing no power out. I have the K line. The relay clicks when going from 11 to 12 watts. I can set the power up to 110, but when I hit tune I get zere watts shown and verified by my

Re: [Elecraft] K3 - No Power Out, Error Message "ERR PL-1"

2017-06-21 Thread Don Wilhelm
Ed, Turn to page 70 in the K3 manual and try the correction steps listed for the ERR PL-1 error. If that does not correct it, contact K3support for further steps. 73, Don W3FPR On 6/21/2017 8:53 AM, Ed Gilliland wrote: No power out 5W calibration fails The error message "ERR PL-1" appears

[Elecraft] K3 - No Power Out, Error Message "ERR PL-1"

2017-06-21 Thread Ed Gilliland
No power out 5W calibration fails The error message "ERR PL-1" appears briefly when I change bands. Thanks for the help. Ed __ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/

Re: [Elecraft] [K3] No Power out, no sigs in

2017-04-15 Thread Geoff Allsup
I had similar trouble related to the synthesizer boards on a K3. On the newer KSYN3A boards there is a green LED on the top edge of the board that should be ON if the board is working ok. You mentioned a sub RX so you should have two of these boards mounted against the back of the front panel.

[Elecraft] [K3] No Power out, no sigs in

2017-04-15 Thread Martin
Elecrafters, i'm on vacation at a /p qth and K3 #2878 has quit working. I have no power out. The display reads 0.0 watts when holding the tune button, regardless of mode. In RX I hear noise from the headphones , but no signals. The noise sounds like the K3 sounds when no antenna is attached. I

Re: [Elecraft] K3 No power out and no receive

2015-09-30 Thread Don Wilhelm
The manual indicates that you should contact K3 support and give then that number. 73, Don W3FPR On 9/30/2015 8:59 AM, way235 wrote: This is a K3 kit and is 6 months old bought April this year. I am going back thru initial setup and getting E 00044 ERR VC4 in calibration both A and B VCO. at

Re: [Elecraft] K3 No power out and no receive

2015-09-30 Thread way235
This is a K3 kit and is 6 months old bought April this year. I am going back thru initial setup and getting E 00044 ERR VC4 in calibration both A and B VCO. at this time. Worked perfect until yesterday. -- View this message in context: http://elecraft.365791.n2.nabble.com/K3-No-power-out-and

Re: [Elecraft] K3 No power out after idle time

2014-09-29 Thread Andy Wood
Hi Jack, I have had this exact problem. Turned out to be the connector between the front panel and main pcb. Treatment with Deoxit has cured it. BTW - I also had some other weird, seemingly unrelated, problems that would occur randomly. The Deoxit treatment cured all of those as well. Andy VK4K

[Elecraft] K3 No power out after idle time

2014-09-29 Thread Jack Berry via Elecraft
This symptom makes me think of edge connector problems I have heard about. But in my case there are no low voltage errors that seems to be the case in other reports. If I cycle the radio off and back on everything is good. I think this is the third time this has happened, all in the last month.

Re: [Elecraft] K3 - No Power Out

2014-01-27 Thread Richard Thorne
After speaking with Howard at Elecraft we have determined that it is probably the lower power amp. It's boxed up and will be on its way back to Elecraft tomorrow. Rich - N5ZC On 1/27/2014 8:17 PM, Gary Smith wrote: Could you have accidentally bumped the "TEST" selection on the mode switch? G

Re: [Elecraft] K3 - No Power Out

2014-01-27 Thread Gary Smith
Could you have accidentally bumped the "TEST" selection on the mode switch? Gary KA1J > I was working stations on and off today. > > Came back into the shack this evening and tried to work a VK on 15m > and > I had no output power. > > I turned the power dial and it was at 0 watts, no problem

[Elecraft] K3 - No Power Out

2014-01-25 Thread Richard Thorne
I was working stations on and off today. Came back into the shack this evening and tried to work a VK on 15m and I had no output power. I turned the power dial and it was at 0 watts, no problem just turn it up. Normally I would progress a 1/10 of a watt at a time up to 12 watts then it woul

Re: [Elecraft] K3 no power out

2013-05-13 Thread Ian White
G3PJT wrote: >Just an update on the no power problem I reported last month. >After checking a series of RF voltages using a checklist from Gary I >located the problem as no RF from the KREF3 board at J65 I then removed >the KREF board and all the cables, inspected board and re assembled the >K

[Elecraft] K3 no power out

2013-05-12 Thread Bob G3PJT
Hi Just an update on the no power problem I reported last month. After checking a series of RF voltages using a checklist from Gary I located the problem as no RF from the KREF3 board at J65 I then removed the KREF board and all the cables, inspected board and re assembled the KREF3 and reinsta

Re: [Elecraft] K3 no power out

2013-04-24 Thread Bob Whelan
5w and a dummy load 73 Bob -- View this message in context: http://elecraft.365791.n2.nabble.com/K3-no-power-out-tp7572990p7573003.html Sent from the Elecraft mailing list archive at Nabble.com. __ Elecraft mailing list Home: http://m

Re: [Elecraft] K3 no power out

2013-04-24 Thread K2GN
craft-boun...@mailman.qth.net] On Behalf Of David F. Reed Sent: Wednesday, April 24, 2013 09:08 To: Bob G3PJT Cc: elecraft@mailman.qth.net Subject: Re: [Elecraft] K3 no power out Bob, when you are in "TUNE", what is PWR set to? You can check by turning that knob; just make sure the LED under PWR

Re: [Elecraft] K3 no power out

2013-04-24 Thread David F. Reed
Bob, when you are in "TUNE", what is PWR set to? You can check by turning that knob; just make sure the LED under PWR is lit, not the one under CMP... The setting is independently adjustable from the power setting while in transmit. Also, just out of curiosity, are you feeding a dummy load o

[Elecraft] K3 no power out

2013-04-24 Thread Bob G3PJT
Hi Suddenly K3/100 serial 3650 refuses to give power out. Setup is - VOX is on (SSB and CW) - not in TEST - CONFIG TX INH is OFF - CONFIG KXV3 is nor - No output when TUNE Firmware reloaded and is 4.60, 1.15, 2.80, 2.80 I have reloaded my back up configuration file and it still doesn't work. I

[Elecraft] K3 no power out on DATA

2012-09-06 Thread george
Thanks for all of the help regarding my audio issue. Turned bias on as suggested and can hear myself. Selected High, tried to put the additional audio stage in with "3" on the mike menu; but, get a response "N/A". Have yet to find the right combination to get sufficient audio out of the mike. I

Re: [Elecraft] K3 no power out on DATA

2012-09-04 Thread vk4tux
ginal Message- From: Adrian Fewster [mailto:a.fews...@pf.uq.edu.au] Sent: Tuesday, September 04, 2012 16:53 PM To: k...@centurytel.net Subject: RE: [Elecraft] K3 no power out on DATA “comp is at zero. Line level was set up and adjusted up some. I do not remember the level right now but I did get

Re: [Elecraft] K3 no power out on DATA

2012-09-04 Thread Mike Sanders
[mailto:w3...@embarqmail.com] Sent: Tuesday, September 04, 2012 16:54 PM To: Mike Sanders Cc: Elecraft Reflector Subject: Re: [Elecraft] K3 no power out on DATA Mike, That sounds to me as though you have the input set for MIC rather than line in, or something similar. First I would suggest using Line

Re: [Elecraft] K3 no power out on DATA

2012-09-04 Thread Don Wilhelm
Mike, That sounds to me as though you have the input set for MIC rather than line in, or something similar. First I would suggest using Line In and use DATA mode (AFSK A submode), select Line In in the MIC SEL menu. Set the K3 into TX TEST (or set the power down and operate into a dummy load)

Re: [Elecraft] K3 no power out on DATA

2012-09-04 Thread Joe Subich, W4TV
The K3 stores input selection (mic - front | rear, or line) and mic level/line level on a per mode and per band basis. Have you set up the input and mic/line levels correctly in DATA A/AFSK A on each band? 73, ... Joe, W4TV On 9/4/2012 4:31 PM, Mike Sanders wrote: > Well, Only days old he

[Elecraft] K3 no power out on DATA

2012-09-04 Thread Mike Sanders
Well, Only days old here the new K3 is still challenging me. Lots of fun without doubt. Anyway I am running MMTTY and using AFSK in the data mode. Everything looks good but no output. I tried shifting to USB/LSB and output is as set on power control. Tones on monitor and another RX sound good as we

[Elecraft] K3 - No power out on 6M

2010-08-03 Thread Ed K1EP
I haven't used my K3 in a couple of weeks, but the thought of working some Au tonight got me going. I turned on the radio, connected the antenna and I could only get 5 or 6 watts out with the PA and 0.1 watts under the 12W setting. The power didn't vary at all with the power control, except w