ESD in Power Station

1999-03-31 Thread bma
Hi, Please allow me to pose two questions. (1) What did Mike Hopkins and Scott Douglas really feel and smell about electricity in the air when these two boys went to electricity stations with their fathers? My guess -- that's air ions and ozone, which are easily produced in a strong AC EM

RF safety emission in Israel

1999-03-31 Thread Barbara Bloodhart
My company is planning to ship cellular phones, some with computers on board, to Israel can somebody help me with the any of the following, especially in the area of RF safety emission: Official standards, compliance testing, and certification of products. Also does anybody know of a company

Fw: RE: Ferrite pads vendors

1999-03-31 Thread ed . price
Posted for Darrel Upson: From: Upson, Darrel darrell.up...@usa.xerox.com Subject: RE: Ferrite pads vendors Date: Wed, 31 Mar 1999 07:38:49 -0800 To: 'emc-pstc group' emc-p...@majordomo.ieee.org Fair-Rite Products Corp. makes pads that go under the IC's.

RE: EMC for automation control - Electricity utilities (UNIPEDE )

1999-03-31 Thread ed . price
Traditional mechanical wristwatches use an escapement wheel which rotates first clockwise, storing the energy of its momentum into a small spring, then stopping and being accelerated counter-clockwise by the spring, and finally re-storing the energy back into the spring. This brass wheel has

RE: EN 60950 productionline test

1999-03-31 Thread Constantin Bolintineanu
Dear colleagues, I think that it is useful for all of us to read the SCOPE of the Standard EN50116: This European Standard defines the routine electrical safety tests and their procedures to be applied during or after the manufacturing process of equipment certified or declared as complying with

RE: EMC for automation control - Electricity utilities (UNIPEDE )

1999-03-31 Thread Schanker, Jack
For what it's worth, I recall wind-up watches with cases which were labelled non-magnetic. My assumption is that a magnetic field can affect the movement, although I wouldn't think an AC magnetic field would matter unless it was very strong. A more likely reason for not wearing watches (or

RE: About 89/336/EEC

1999-03-31 Thread Helge Knudsen
Hello Tetsuya, The publication in OJ on 1999/02/27 was not a new directive, it was a list of those standards which may be used to demonstrate compliance with the EMC Directive, 89/336/EEC. The EMC Directive does not cover medical devices since June 1998, you have to use the Medical Device

Re: Ferrite pads vendors

1999-03-31 Thread Tony J. O'Hara
Just for clarification, Kitagawa and INTERMARK (which has already been identified as a maufacturer of Ferrite IC pads) are one and the same companies. In USA use INTERMARK-21-629-3620 or www.ingress.com/~im-usa Tony O'Hara LARCTEC Marketing Colorado Hello group, there is a company called

ESD Troubleshooting

1999-03-31 Thread Allen Tudor
Does anyone have a suggestion on how to troubleshoot ESD problems? Specifically, I am having a problem with contact discharge to a metal chassis. The first thing that comes to mind would be to check for ground bounce with an oscilloscope when the ESD gun is discharged. For example, I thought

RE: EMC for automation control - Electricity utilities (UNIPEDE )

1999-03-31 Thread Robert Macy
IMHO the magnetic fields go right through the watch case and either disrupt what's going on or can even magnetize the parts. Either way, the parts are like stuck together and the watch won't run well. Also, my father could never wear a watch, a great gift watch always would stop. The same watch

Re: EN 60950 productionline test

1999-03-31 Thread Scott Douglas
Kim, The standard is: EN 50116 : 1996, Information technology equipment - Routine electrical safety testing in production. This can also be obtained as: BS EN 50116 : 1996 from BSI or other sources. The actual standard is only 1.5 pages long. Scott s_doug...@ecrm.com

RE: EN 60950 productionline test

1999-03-31 Thread WOODS, RICHARD
The original message indicated that the writer thought that this standard is under the LVD. I cannot find this standard published in the OJ as being required under the LVD; therefore, I must assume that its use is not a condition of adding the CE mark. So its use is voluntary unless an agency

Re: Is there any correlation between VW-1 wire and UL 94 V-1 ?

1999-03-31 Thread Robert Tims
Hi Terry, To answer your question bluntly, NO, there is no correlation between VW-1 and UL94V-1,HF-1, etc. The VW-1 rating is a flame test and rating performed on wire and cable constructions only. The combination of the wire, plus any insulstion, jacket, shielding, or taping, and coloring, is

RE: Ferrite pads vendors

1999-03-31 Thread brian_kunde
TDK sent me several sheets of Ferrite material as samples. The material is very flexible and can be cut to any shape with scissors. I do not know if TDK provides this material in pre-cut sizes for IC Chips or have it available with PSA. I have not had an opportunity to try this material so I

I/O Surge

1999-03-31 Thread WOODS, RICHARD
EN50130-4, Immunity for alarm systems, requires that signal lines be surge tested per EN6100-4-5 using the coupler/decoupler network in figure 12 for balanced signal pairs. The equipment available on the market has a bandpass rating of 100 kHz, and the standard does not specify the type of

RE: Is there any correlation between VW-1 wire and UL 94 V-1 ?

1999-03-31 Thread Jody Leber
Terry, If you step back in the list it specifically allows openings in the bottom of any size under: PVC, TFE, PTFE, FEP and neoprene insulated conductors and their connectors Best Regards, Jody Leber jle...@ustech-lab.com http://www.ustech-lab.com U. S. Technologies 3505 Francis Circle

RE: EN 60950 productionline test

1999-03-31 Thread Constantin Bolintineanu
The Standard is: INFORMATION TECHNOLOGY EQUIPMENT. ROUTINE ELECTRICAL SAFETY TESTING IN PRODUCTION. The number is EN50116:1996 Respectfully yours, Constantin Bolintineanu Constantin Bolintineanu, P.Eng. Product Safety Engineer DIGITAL SECURITY CONTROLS LTD. 1645 FLINT Rd. TORONTO , ONTARIO, CANADA

RE: Is there any correlation between VW-1 wire and UL 94 V-1 ?

1999-03-31 Thread John Juhasz
VW stands for 'Vertical Wire' test. This applies to wires only. It is however, the best class. 94 V series is the UL 94 standard, Vertical positioning of the test sample. V-0 is the best rating. John A. Juhasz Product Qualification Compliance Engr. Fiber Options, Inc. 80 Orville Dr. Suite 102

RE: Ferrite pads vendors

1999-03-31 Thread John Juhasz
Yes!! I got a sample for some EMC testing and it worked pretty well. Get in touch with: Intermark (USA) Inc. One Penn Plaza New York, NY 10119-0001 (212) 629-3620Fax:(212) 967-3948 John A. Juhasz Product Qualification Compliance Engr. Fiber Options, Inc. 80 Orville Dr. Suite 102 Bohemia,

RE: Ferrite pads vendors

1999-03-31 Thread Allan, James
Steward in Chattanooga (615) 867-4100 also makes them but I would not put much hope in them being a cure-all. Jim Allan Senior Compliance Engineer Milgo Solutions Inc -Original Message- From: salba...@hns.com [SMTP:salba...@hns.com] Sent: Tuesday, March 30,

EN 60950 productionline test

1999-03-31 Thread kim . boll . jensen
Dear groupe, For a year ago I got a standard under the LVD which called for a productionline test with HV test and earth test. I have now lost that information and would like if someone can help me with the number and name of the standard, it addresses IEC 950 equipment. Best regards, Mr. Kim

Re: Ferrite pads vendors

1999-03-31 Thread IScheyer
Hello group, there is a company called KITAGAWA GmbH. They showed these ferrite pads on the EMV'99 in Düsseldorf, Germany. For further information try to contact Mr. Peter Mangold at: kitagawa-sa...@t-online.de Have you ever used these pads? Do you have any experience with them? Please

Electromagnetic Waves and Lights

1999-03-31 Thread bma
Hi, A colleague of the group asked a question about Electromagnetic (EM) waves and lights last week. I accidentally deleted it. Please allow me to input the following in response to his question. All lights are essentially EM waves. Lights differ from ordinary EM waves only in shorter

IEC 61000-3-2 Update and EMC workshop

1999-03-31 Thread George, David L
Since there is still some confusion of the subject of power EMC, the following workshop may be of interest to the members of this forum. Dave George Unisys ___ To All, The second USCCEMC Harmonics Workshop will be held May 6th

Re:Ferrite pads vendors

1999-03-31 Thread Tony J. O'Hara
INTERMARK USA at 212-629-3620 makes these. Web is www.ingress.com/~im-usa Tony O'Hara LARCTEC Marketing Colorado - This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to majord...@ieee.org with the single line: unsubscribe emc-pstc (without

RE: EMC for automation control - Electricity utilities (UNIPEDE )

1999-03-31 Thread Mike Hopkins
Very interesting -- my father also worked for what was then New England Power and was a substation operator in Tewksbury, MA -- he also went to other smaller sub-stations to switch lines in or out for maintence or to clear trouble problems and I have similar recollections about the electricity in