Re: [Emc-users] Rigid Tapping in U,V,W

2016-02-13 Thread TJoseph Powderly
thanks todd i also used the offset component so it sounds familiar the offset component was returned to original position simply by nudging till offset was 0 tomp On 02/14/2016 06:54 AM, Todd Zuercher wrote: > I'm not quite sure I understood your reinterpretation of what I tried to > explain. h

Re: [Emc-users] Rigid Tapping in U,V,W

2016-02-13 Thread Todd Zuercher
From: "TJoseph Powderly" To: "Enhanced Machine Controller (EMC)" Sent: Saturday, February 13, 2016 10:59:27 AM Subject: Re: [Emc-users] Rigid Tapping in U,V,W Thanks Todd before i dig into your code, i read the thread and if i understand correctly, then i can rephrase what you d

Re: [Emc-users] Rigid Tapping in U,V,W

2016-02-13 Thread TJoseph Powderly
Thanks Todd before i dig into your code, i read the thread and if i understand correctly, then i can rephrase what you did ( my standard test for whether i understand ;-) i think you commanded W and added the delta to the W while the custom M code was in effect. true? i did similar for sink edm

Re: [Emc-users] Rigid Tapping in U,V,W

2016-02-13 Thread Todd Zuercher
-questions?start=20#70064 - Original Message - From: "robert - Innovative-RC" To: "Enhanced Machine Controller (EMC)" Sent: Saturday, February 13, 2016 8:54:12 AM Subject: Re: [Emc-users] Rigid Tapping in U,V,W yes you can tap in X Y Z no problem, if you try it out in the 9

Re: [Emc-users] Rigid Tapping in U,V,W

2016-02-13 Thread robert - Innovative-RC
yes you can tap in X Y Z no problem, if you try it out in the 9axis sim you can see U V W does not follow spindle just goes to position in the G code, and then proceeeds to the next line of code with no error etc even if you switch planes or (G18 or G17.1) my config is on a 3 axis lathe X Z top

Re: [Emc-users] Rigid Tapping in U,V,W

2016-02-13 Thread Todd Zuercher
quot; Sent: Saturday, February 13, 2016 4:50:15 AM Subject: [Emc-users] Rigid Tapping in U,V,W hi what would it take to add or finish adding U V W rigid tapping ? as i see when you command G33.1 with a W it is accepted but goes to postion and just does the next line of code with out doing the

[Emc-users] Rigid Tapping in U,V,W

2016-02-13 Thread robert - Innovative-RC
hi what would it take to add or finish adding U V W rigid tapping ? as i see when you command G33.1 with a W it is accepted but goes to postion and just does the next line of code with out doing the tapping move. so it looks like someone might have started adding rigid tapping in U V W? i use a