Does anyone know if they have updated the z/VM cookbook for 5.3 yet?
I assume you mean The Virtualization Cookbook. Not yet. I installed 5.3
using the 5.2 recipes and the two are almost identical. We do hope to get
both the latest books for SLES 10 and RHEL 5 on linuxvm.org/present
converted
Depending on what options your site chooses to use (PerfKit, Dirmaint,
RACF, etc.) configuring z/VM 5.3 can take a lot more time than the
installation step.
Michael MacIsaac wrote:
Does anyone know if they have updated the z/VM cookbook for 5.3 yet?
I assume you mean The Virtualization
Given that I¹m just about to try this, I¹d like to hear the funny story just
as soon as you¹re ready to relate it.
--
.~.Robert P. Nix Mayo Foundation
/V\RO-OE-5-55 200 First Street SW
/ ( ) \ 507-284-0844 Rochester, MN 55905
^^-^^ -
Thanks for the replies. And thanks for the TRACK commands, Mike. I use
TRACK all the time but mostly for viewing consoles. TRACK shows an
active I/O to a VSWITCH connected to an OSAX. I am reluctant to do a
HALT on that device as I do not know if it would impact other users of
the VSWITCH.
We have a situation where a virtual machine, VSEDEV2, was forced. This
virtual machine was using a virtual switch, DTCVSW2, via a NIC using
virtual addresses e00, e01, and e02.
Track indicates VSEDEV2 is waiting for I/O on virtual address E02.
We have production vse images as well as the Z/VM
Hello Everyone,
Is it possible that the PC that can not connect can be rebooted?
(It what you do with a PC).
In the TN3270 you may have LU or PORT name that is being kept in
memory for that connection, so you can not start another one until that
LU/PORT in memory has been
On Tuesday, 09/11/2007 at 02:05 EDT, Hughes, Jim [EMAIL PROTECTED]
wrote:
We have a situation where a virtual machine, VSEDEV2, was forced. This
virtual machine was using a virtual switch, DTCVSW2, via a NIC using
virtual addresses e00, e01, and e02.
Track indicates VSEDEV2 is waiting for
How do I kill this I/O so the VSE system can finish its
logoff/shutdown sequence?
Jim Hughes
603-271-5586
There's no sense in being precise when you don't even know what you're
talking about.
John von Neumann
=-Original Message-
=From: The IBM z/VM Operating
On Tuesday, 09/11/2007 at 02:18 EDT, Hughes, Jim [EMAIL PROTECTED]
wrote:
How do I kill this I/O so the VSE system can finish its
logoff/shutdown sequence?
What makes you think that the I/O to E02 is what is holding up the VSE
shutdown? Mind you, I'm not necessarily disagreeing, but I'm
The only thing I have to go on right now is the output of the TRACK
command. It only shows IO for VSEDEV2 on E02. No other I/O's are active
or pending.
I would look somewhere else if I knew where to look.
Jim Hughes
603-271-5586
There's no sense in being precise
On Tuesday, 09/11/2007 at 02:33 EDT, Hughes, Jim [EMAIL PROTECTED]
wrote:
The only thing I have to go on right now is the output of the TRACK
command. It only shows IO for VSEDEV2 on E02. No other I/O's are active
or pending.
I would look somewhere else if I knew where to look.
The I'd
Jim,
Terminating the TCP/IP partition in VSE should shutdown the OSA
interface. TCP/IP partition shutdown (in either vendors product) should
cause a call to be made to the $IJBOSA with a terminate function. If the
OSA is running in OSA/2 mode then a simple SVC 25 is used to halt the
I/O operation
How do you issue the CP DETACH E00 (in your example below) if the user is
in a FORCE PENDING state?
Alan Altmark [EMAIL PROTECTED]
Sent by: The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
09/11/2007 02:26 PM
Please respond to
The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
On Tuesday, 09/11/2007 at 03:30 EDT, [EMAIL PROTECTED] wrote:
How do you issue the CP DETACH E00 (in your example below) if the user
is in a
FORCE PENDING state?
You don't. That's what you could issue if VSE won't shutdown in response
to, say, the CP SIGNAL SHUTDOWN command. Once a user
Lionel:
I just experienced shopzseries for the first time. To say it
was interesting is an understatement.
If a user has a problem or question related to their ShopzSeries
experience, they should use the contact information on the
Customer service page to get support.
I used it to order z/vm
15 matches
Mail list logo