Re: HCPCLS174E Paging I/O error; IPL failed - on second level z/VM

2007-03-20 Thread Stefan Raabe
M z/VM Operating System 19.03.2007 22:07 Please respond to The IBM z/VM Operating System To IBMVM@LISTSERV.UARK.EDU cc Subject Re: HCPCLS174E Paging I/O error; IPL failed - on second level z/VM Stefan, As already mentioned, this looks suspiciously like you did not fully format ALL cyl

Re: HCPCLS174E Paging I/O error; IPL failed - on second level z/VM

2007-03-19 Thread Mike Walter
re mine alone and do not necessarily represent the opinions or policies of Hewitt Associates. "Stefan Raabe" <[EMAIL PROTECTED]> Sent by: "The IBM z/VM Operating System" 03/19/2007 10:12 AM Please respond to "The IBM z/VM Operating System" To IB

Re: HCPCLS174E Paging I/O error; IPL failed - on second level z/VM

2007-03-19 Thread RPN01
Did you format the entire paging space? It needs to be pre-defined with 4k page blocks before it can be used. CMS minidisk volumes can be defined using ICKDSF by just formatting cyl 0 to contain the correct label, and everything will handle formatting their small piece of the world when the time c

HCPCLS174E Paging I/O error; IPL failed - on second level z/VM

2007-03-19 Thread Stefan Raabe
Hello List, i was working on a a second level VM (z/VM 5.2, 5203RSU applied) when i got these messages after IPL when trying to log on users: HCPCLS174E Paging I/O error; IPL failed HCPCLS059E AUTOLOG failed for AUTOLOG1 - IPL failed I was running with 384 Meg, so i made it 512meg and after