(RADIATOR) proxying Acct?

1999-07-22 Thread Ricardo Kustner
Hi, our setup is like this right now Auth: Ascend --> radiator (sql) --> radiusd1 (/etc/passwd) Acct: Ascend --> radiusd2 radiusd1 is a unix machine which authorizes some of our old accounts through the local passwd file. radiusd2 is another unix machine which logs the accounting and runs some

(RADIATOR) Simultaneous-Use

1999-07-22 Thread Ben-Nes Michael
Hi All from the manual: "Radiator keeps track of the number of current sessions for a user by counting the Accounting Start and Stop requests received for that user" What happened if one of my users is logging out while my Frame relay between my POP's is down. as i know there will be no stop rec

Re: (RADIATOR) Simultaneous-Use

1999-07-22 Thread tom minchin
On Thu, Jul 22, 1999 at 02:19:27PM +0200, Ben-Nes Michael wrote: > Hi All > > from the manual: "Radiator keeps track of the number of current sessions > for a user by counting the Accounting Start and Stop requests received > for that user" > > What happened if one of my users is logging out whi

Re: (RADIATOR) Simultaneous-Use

1999-07-22 Thread Ben-Nes Michael
But if the FR got up again can the Radius check if the users are still there ? tom minchin wrote: > On Thu, Jul 22, 1999 at 02:19:27PM +0200, Ben-Nes Michael wrote: > > Hi All > > > > from the manual: "Radiator keeps track of the number of current sessions > > for a user by counting the Accounti

(RADIATOR) oracle

1999-07-22 Thread Ricardo Guerra
Hi! How can i authenticate using oracle on a remote machine?? where should i setup the host and port where radiator must serch for oracle? === Archive at http://www.thesite.com.au/~radiator/ To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.

(RADIATOR) Need Help

1999-07-22 Thread Dwayne Godden
I'm Trying to Authenticate to a Windows NT server 4 and I get regected can some help with the config.   Domain Name = Hardnet Domain controler = Nix   I have looked in all the docs I have and none of what it tels workes   thankyou.   Dwayne Godden..

Re: (RADIATOR) Simultaneous-Use

1999-07-22 Thread tom minchin
On Thu, Jul 22, 1999 at 03:58:54PM +0200, Ben-Nes Michael wrote: > But if the FR got up again can the Radius check if the users are still there ? > No, (unless the period of outage is very short and the NAS is still sending retransmitted stops to the RADIUS server - most NAS have a limit on how

Re: (RADIATOR) oracle

1999-07-22 Thread John Coy
You'll need to define the remote database in your tnsnames.ora file, like this: -- tnsnames.ora -- remote_database= (DESCRIPTION= (ADDRESS= (PROTOCOL=TCP) (HOST=WWW.XXX.YYY.ZZZ) (PORT=) ) (CONNECT_DATA=(SID=WG73)) )

(RADIATOR) Call-check

1999-07-22 Thread Dave Close
My Lucent (Livingston) PortMasters are capable of using a feature named "call-check". With this feature, the PM sends an authentication request before it accepts an incoming call. The request specifies the phone-number from which the call is coming as the user name. Radius has the opportunity

(RADIATOR) NAS' in Multiple Timezones, AAA in One ?

1999-07-22 Thread Brad Vonarx - AAPTN VicOne
Has anybody dealt with this issue ? I have Access Servers Australia wide, however Radiator servers in Melb and Syd only.I need to display the time the caller connected locally not the Radiator local time. Then the issue gets more complicated during daylight savings time, any Ideas ? === Arch

Re: (RADIATOR) NAS' in Multiple Timezones, AAA in One ?

1999-07-22 Thread tom minchin
On Fri, Jul 23, 1999 at 08:17:00AM +, Brad Vonarx - AAPTN VicOne wrote: > > Has anybody dealt with this issue ? I have Access Servers Australia wide, > however Radiator servers in Melb and Syd only.I need to display the > time the caller connected locally not the Radiator local time. Then

Re: (RADIATOR) Call-check

1999-07-22 Thread Bernd Strehhuber
Hi, > I have over 100 PortMasters world-wide and I'd like to use this feature > on most of them. I've done that on my Livingston Portmaster 3 to provide Callback based on the Callers CLI. First you must put a line into your dictionary File: VALUE Service-TypeCall-Check

Re: (RADIATOR) NAS' in Multiple Timezones, AAA in One ?

1999-07-22 Thread Jeremy Burton
On Fri, Jul 23, 1999 at 08:17:00AM +, Brad Vonarx - AAPTN VicOne wrote: > > Has anybody dealt with this issue ? I have Access Servers Australia wide, > however Radiator servers in Melb and Syd only.I need to display the > time the caller connected locally not the Radiator local time. Then

Re: (RADIATOR) Radius stress test anyone ??

1999-07-22 Thread Mike McCauley
Hi Paul, On Jul 21, 8:18pm, Paul van der Zwan wrote: > Subject: (RADIATOR) Radius stress test anyone ?? > > I am looking for a stress test for a radius server. > Using radpwtst on a single host I see 2 requests/sec serviced by the > radiator server ( which is > 95 % idle). > Does any of you know

Re: (RADIATOR) Swapping Parameters

1999-07-22 Thread Mike McCauley
Hello Requiem, On Jul 21, 5:59pm, Requiem Aurelien (Ext/NTC) wrote: > Subject: (RADIATOR) Swapping Parameters > Hello > > Does any one know how to swap (exchange) > parameters just a the beginning of the request. > (Before everything even logfile and > accountingLog file In version 2.14, PreAut

(RADIATOR) Radacct.cgi ->> Help

1999-07-22 Thread Michael Gatti
Hello;   Is anyone using the radacct.cgi for the internauts to look at there internet usage ??? We're testing this solution here at my ISP and I would like some help at the radacct.cgi file's config.   Thanx   Regards Michael Gatti Malbanet Servicos Online  

No Subject

1999-07-22 Thread Rajesh K
Hello all! Is it possible to use two different user files in radiator. Also does the sorting of the userfile improves the speed of authentication . Rajesh Get your own FREE, personal Netscape WebMail account today at http://w

Re: (RADIATOR) Duplicate key in object 'Calls'

1999-07-22 Thread Mike McCauley
Hi John, The message you are seeing is "normal" in the sense that the insert is trying to insert a retransmitted accounting request. This is undoubtedly due to the accounting response being lost on the way back to the NAS. This is also an artifact of the radius protocol, being based on UDP. You

Re: (RADIATOR) Multiple instances of the same username ??

1999-07-22 Thread Mike McCauley
Hi Gary, It is not possible to have 2 different users with teh same username in the same users file. If the users are indeed different, you can specify a different Handler for each different number, and have a separate user database for each Handler. Alternatively you could chain 2 clauses, wit

Re: (RADIATOR) proxying Acct?

1999-07-22 Thread Mike McCauley
Hello Ricardo, its not possible to change the AuthByPolicy in the middle of a Realm. Instead, we would suggest doing it like this (untested): # Handle all acccounting requests here AuthByPolicy ContinueAlways # Alweays save accoutning to an SQL database

Re: (RADIATOR) Need Help

1999-07-22 Thread Mike McCauley
Hi Dwayne, 2 things: On NT, it is often not necessary to sepcify DomainController, your Radiato will figure it out. But if you do specify a DomainController on NT, you will need to include the leading slashes on the machine name (ie standard MS machine naming convention) Hope that helps. Cheers

(RADIATOR) Ascend To Raditor config

1999-07-22 Thread Dwayne Godden
I've now got Raditor to talk to windows NT, But now I'm have the problem with my Ascen MAX 6000 unit. Is there some DOC's on how to do this or has anyone done this befor and can lend a hand?.   Thankyou Dwayne Godden..

Re: (RADIATOR) Multiple instances of the same username ??

1999-07-22 Thread Gary
On Fri, 23 Jul 1999 15:19:42 -0500, Mike McCauley wrote: >Hi Gary, > >It is not possible to have 2 different users with teh same username in the same >users file. > >If the users are indeed different, you can specify a different Handler for each >different number, and have a separate user databas

Re: (RADIATOR) NT

1999-07-22 Thread Mike McCauley
> > Hi, > > We just purchased Radiator and need to setup a configuration > file to work with an NT domain. We modified the radius/cfg > file down to the NT authorization but it does not work. We > keep getting these error messages when using the password > test script. > > Debug - Check if handle

Re: (RADIATOR) Call-check

1999-07-22 Thread Mike McCauley
Hi Dave, On Jul 22, 11:23am, Dave Close wrote: > Subject: (RADIATOR) Call-check > My Lucent (Livingston) PortMasters are capable of using a feature named > "call-check". With this feature, the PM sends an authentication request > before it accepts an incoming call. The request specifies the > ph

Re: (RADIATOR) NAS' in Multiple Timezones, AAA in One ?

1999-07-22 Thread Mike McCauley
Hi Brad, On Jul 23, 8:17am, Brad Vonarx - AAPTN VicOne wrote: > Subject: (RADIATOR) NAS' in Multiple Timezones, AAA in One ? > > Has anybody dealt with this issue ? I have Access Servers Australia wide, > however Radiator servers in Melb and Syd only.I need to display the > time the caller c

Re: (RADIATOR) Ascend To Raditor config

1999-07-22 Thread Mike McCauley
Hi Dwayne, On Jul 23, 4:06pm, Dwayne Godden wrote: > Subject: (RADIATOR) Ascend To Raditor config > > I've now got Raditor to talk to windows NT, But now I'm have the problem with my Ascen MAX 6000 unit. Is there some DOC's on how to do this or has anyone done this befor and can lend a hand?. I

No Subject

1999-07-22 Thread Mike McCauley
Hi Rajeesh, On Jul 23, 10:33am, Rajesh K wrote: > Subject: > Hello all! > > Is it possible to use two different user files in radiator. Yes, you can arrange for Radiator to let them in if they are in either file, or if they are in both files. Or you can arrange for one file for one realm, and a d