Hi Wing,
I purchased LaB6 from http://www.thegemdugout.com/ for a fraction of price
NIST charges and the same quality.
Peter Zavalij
X-ray Crystallographic Center
University of Maryland
College Park, MD 20742
Phone: 301-405-1861
From: Julian Tolchard [mailto:tolch
Jin,
Make sure you refine a,b,c in the last refinement cycle. If you fix the at
some points the error "bars" are gone.
Peter Zavalij
X-ray Crystallographic Center
University of Maryland
College Park, MD 20742
Phone: 301-405-1861
From: Peng, Jin [mailto:jpe...@
Thanks Armel,
I did told author of this request about my book.
I didn't reply to whole list - it does not seem right to advertise (too
much) your own work. This can even have negative impact.
Peter
Dr. Peter Y. Zavalij
Director, X-ray Crystallographic Laboratory
Department of Chemistry & Bioch
Dear Vikrant,
I don’t think you could write Rietveld program using only online
notes. It may take some learning to get into the methods (in depth learning if
you want to write program).
Dr. Peter Y. Zavalij
Director, X-ray Crystallographic Laboratory
Department of Chemistry & Biochemis
the refinement.
Otherwise we run into another problem when
changes in atomic coordinates do not move atom to different site.
Peter Zavalij
From: Brian Toby
[mailto:[EMAIL PROTECTED]
Sent: Tuesday, May 17, 2005 11:20
AM
To: rietveld_l@ill.fr
Subject: Re: mismatch between ICSD
cif
a on a CD-ROM:
Fundamentals of Powder Diffraction and Structural Characterization of
Materials by Vitalij Pecharsky and Peter Zavalij, Springer, 2003, ISBN:
1-4020-7365-8.
http://www.springeronline.com/sgw/cda/frontpage/0,11855,4-40109-22-39525831-
0,00.html
Though due to its price - it might be
cupancies can be exposed - maybe.
Thus to end I would recommend looking for trends rather than just
looking at a single sample and believing the refinement results.
Alan
-Original Message-----
From: Peter Zavalij [mailto:[EMAIL PROTECTED]
Sent: Thursday, May 05, 2005 8:16 PM
To: rietveld
the limit is
reached there's a phase transition. It may very well be the case that
your system has no vacancies but I would not assume it at first.
alan
-Original Message-----
From: Peter Zavalij [mailto:[EMAIL PROTECTED]
Sent: Thursday, May 05, 2005 6:44 PM
To: rietveld_l@ill.fr
We
http://icpet-itpce.nrc-cnrc.gc.ca
-Original Message-
From: Peter Zavalij [mailto:[EMAIL PROTECTED]
Sent: May 5, 2005 11:36 AM
To: rietveld_l@ill.fr
Alexander:
I just finished combined X+N refinement of similar battery materials but w/o
V with Li in 2a site and Mn, Co and Ni in 2b (or vis
Alexander:
I just finished combined X+N refinement of similar battery materials but w/o
V with Li in 2a site and Mn, Co and Ni in 2b (or vise versa).
Chemical composition was well known; The problem we were looking for was
migration/exchange of transition metal from 2b to 2a.
That's not so simple p
Wow! 5 month of vacations, no wonder it's confidential.
Peter Y. Zavalij
Director, X-ray Crystallographic Laboratory
Department of Chemistry & Biochemistry
091 Chemistry Building
University of Maryland
College Park, MD 20742-4454
Phone: (301)405-1861
Fax: (301)314-9121
E-mail: [EMAIL PROTECTE
There are several function in GSAS for
absorption correction. For Bragg-Brentano geometry the best is Suorti (#3).
This correction (coeff.1 & Coeff.2 in
range of .2-.5) is designed primarily for porosity correction but is does good
job with absorption correction and any other correction th
Yes, it priced very high by publisher. However there is option to order 6 or more
books through university bookstore and get around
30% discount. I also heard that some bookstores were able to order for as low as $96
per book.
Peter Zavalij
-Original Message-
From: Lachlan Cranswick
Or
newer book
Fundamentals of
Powder Diffraction and Structural Characterization of
Materialsat
http://www.springeronline.com/sgw/cda/frontpage/0,0,4-0-22-33289750-0,0.html?referer=www.springeronline.com/isbn/1-4020-7365-8
http://www.sciencedirect.com/science?_ob=MImg&_imagekey=B6X1J-4CKJV
2a & 2b yield the same structure that has c'=c/2 so this is not case.
2c & 2d yield again the same structure which is hexagonal close-packed - Mg structure
type.
Check cell dimensions against know structure types.
Peter Zavalij
University Crystallographer
Institute for Materials
Do you know what structure type it is? If yes just take the same atomic position for
you compound as for the known one.
If not you have to find it.
Anyway... be careful with the space group symbol - It should be "P 63/m m c" not "P 6
3 /m m c". NO SPACE between 6 & 3.
Pe
Actually any Extra-hold or Maximum-hold hair spray works fine. I use it not
necessarily on the backload sample but on any spinning
sample even so the sample is horizontal. It's a bit tricky to put but it you keep at
least 25-20 cm distance and do it slowly it
works fine.
Peter
-Original Mess
I believe the PDF-4 database is based on the Microsoft access but I am not sure the
format is public.
Peter Zavalij
University Crystallographer
Institute for Materials Research
and Chemistry Department
Binghamton University, SUNY, Vestal Pkwy, East
Binghamton, NY 13902-6000, USA
Tel: (607)777
cure
for this.
Peter Zavalij
University Crystallographer
Institute for Materials Research
and Chemistry Department
Binghamton University, SUNY, Vestal Pkwy, East
Binghamton, NY 13902-6000, USA
Tel: (607)777-4298Fax: (607)777-4623
E-mail:[EMAIL PROTECTED]
http://materials.binghamton.edu/za
Hi everyone,
Sorry for asking again but I am not sure I send this message first time.
I am looking for an old/used generator for Scintag XDS2000 diffractometer.
New one is too expensive as for old machine.
Any suggestions/contacts are welcome.
Thanks in advance,
Peter Zavalij
University
Simply
use just
Dr. Peter Y. Zavalij University
CrystallographerInstitute for Materials Researchand Chemistry
DepartmentBinghamton University, SUNY, Vestal Pkwy, EastBinghamton, NY
13902-6000, USATel: (607)777-4298 Fax:
(607)777-4623E-mail:[EMAIL PROTECTED]http://materials.binghamton.ed
Hi everyone,
I am looking for an old/used generator for Scintag XDS2000 diffractometer.
New one is too expensive as for old machine.
Any suggestions/contacts are welcome.
Thanks in advance,
Peter Zavalij
University Crystallographer
Institute for Materials Research
and Chemistry Department
ifically for each case...
Peter
Zavalij
University CrystallographerInstitute for Materials
Researchand Chemistry DepartmentBinghamton University, SUNY, Vestal
Pkwy, EastBinghamton, NY 13902-6000, USATel:
(607)777-4298 Fax:
(607)777-4623E-mail:[EMAIL PROTECTED]http://materials.
Reference to PSF #4 by P. Stephens is J. Appl. Cryst. (1999). 32, 281-289.
Peter Y. Zavalij
University Crystallographer
Institute for Materials Research
and Chemistry Department
Binghamton University, SUNY, Vestal Pkwy, East
Binghamton, NY 13902-6000, USA
Tel: (607)777-4298Fax: (607)777-4623
The approach you use describes anisotropy of the peak broadening in ellipsoidal
approximation and it is not strange that fit is
improved. The question is how adequate the model is. You may also try PSF #4.
There was a lot of discussion recently on this list about the anisotropic broadening
and pe
topics and workshops, or anything else you
may wish to bring to our attention.
Sincerely yours,
Peter Zavalij
__
Contact information:
Abraham Clearfield, Chair 04
Dept. of Chemistry
Texas A & M Univ.
PO Box 30012
College Station TX 77843-3255
Tel: 979 845
Brian is right there are no F (holding atomic parameters in EXPGUI). I messed F up
with V.
However I found no problem to remove them using D. Simply type "D #" where # is number
of holding parameter.
To check list of holding parameters (better before and after D) type "L&q
The easiest way is to use EXPGUI graphic user interface by Brian Toby.
Peter Zavalij
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
Sent: Thursday, April 22, 2004 5:05 AM
To: [EMAIL PROTECTED]
Dear all Rietvalders,
Can anyone know how to delete the holding
Maxim,
I think the best way to do incommensurate structure is Jana.
Peter
-Original Message-
From: Maxim V. Lobanov [mailto:[EMAIL PROTECTED]
Sent: Monday, April 12, 2004 4:49 PM
To: [EMAIL PROTECTED]
Dear collegaues,
I would be grateful if somebody could tell me if it is possible to do
>From my experience both functions #3 and #4 work fine when broadening anisotropy is
>not significant.
I found #4 more works better when anisotropy is large (up to 2 times); in this case
improvement is substantial
Peter Zavalij
-Original Message-
From: Maxim V. Lobanov [mailto:
conclusions correct space group symbol with properly placed
spaces has to be used.
Peter Zavalij
-Original Message-
From: Allen Larson [mailto:[EMAIL PROTECTED]
Sent: Wednesday, March 31, 2004 11:58 AM
To: [EMAIL PROTECTED]
Peter Zavalij wrote:
>
> Bob,
> Thank you for the clar
Bob,
Thank you for the clarification. I never had doubts that GSAS handles fixed origin
issue properly but also never understand how it
is done. This way has one big advantage over user fixed origin -- it yields standard
uncertainties for all atoms and therefore for
all distances, etc.
Peter
.
Peter
Zavalij
- Original Message -
From:
Peter
Zavalij
To: [EMAIL PROTECTED]
Sent: Friday, March 26, 2004 12:57
PM
Subject: RE:
This is quite comprehensive question(s) and even not so comprehensive
answer could not be placed in one e-mail
;
P.Y.Zavalij. Kluwer Academic Publishers, Spring 2003. (www.amazon.com, www.wkap.nl)
Peter
Zavalij
-Original Message-From: ling yang
[mailto:[EMAIL PROTECTED]Sent: Friday, March 26, 2004 11:58
AMTo: [EMAIL PROTECTED]Subject:
Dear all,
I have some questions concerning
tal files have to be created for each diffractometer configuration
used (e.g. different slits).
Peter Zavalij
Dr. Peter Y. Zavalij
University Crystallographer
Institute for Materials Research
and Chemistry Department
Binghamton University, SUNY, Vestal Pkwy, East
Binghamton, NY 13902-6000, US
The
best way is to check generated symmetry operations with International tables for
crystallography or on-line using, for example, Bilbao server: http://www.cryst.ehu.es/cryst/get_gen.html which
has all conventional and non-conventional settings and much
more.
Peter
Dr. Peter Y. Zavalij Un
Dear
Nichole,
Space
between 4 and 2 does not make any sense and results in P 4/m m m
symmetry.
BUT
for sure spaces surrounding "/" should be removed and space groups symbol
should as following: "P 42/n m c".
Note
that S is not part of the space group symbol and is probably ignored b
37 matches
Mail list logo