Re: [Therion] Display Station comments on Map?

2019-09-06 Thread Bruce Mutton
Thanks Ben Two new insights for me in your examples. I create surface station maps with flags like in your examples, but have never thought to include a previewed cave map as well - obvious really! And I had not appreciated how to use the -station option for scraps, much easier than drawing the

Re: [Therion] Extended profile problems

2019-09-06 Thread Martin Sluka via Therion
Hi Bill, > 6. 9. 2019 v 17:41, Bill Gee : > > Thanks! This is much better, but still not what I want. I don't want the > profile to fold back on itself at all. I want one continuous profile > extending from OC5a on the left to G14 on the right. Is that possible? I’m not sure if this is pos

Re: [Therion] Detecting errors

2019-09-06 Thread MD
On 6. Sep 2019, at 08:01, Ben Cooper wrote: > > In my experience poor calibration is usually down to either just inaccurate > calibration shots, or local magnetic anomalies: take off watch, step counter, > metal belt buckle, jewellery, glasses, helmet, lights, steel toe caps, etc!! Took your a

Re: [Therion] Detecting errors

2019-09-06 Thread MD
On 6. Sep 2019, at 18:31, Wookey wrote: > > What SD numbers do you use for this? > > I agree they should be different, but I've not seen much research > evidence on what the correct numbers are. Pre-Disto we used https://de.wikipedia.org/wiki/H%C3%A4ngezeug which should result in about the sam

Re: [Therion] Detecting errors

2019-09-06 Thread Wookey
On 2019-08-15 11:50 +0200, Benedikt Hallinger wrote: > To expand a little in this, you could also use the standard „grade“ to tell > theriob which centerline data has which quality. We use this to mark the > centerlines we have surveyed with distox and traditional way and therion uses > this to

Re: [Therion] Extended profile problems

2019-09-06 Thread Bill Gee
Hi Martin - Thanks! This is much better, but still not what I want. I don't want the profile to fold back on itself at all. I want one continuous profile extending from OC5a on the left to G14 on the right. Is that possible? If I draw them as "projection none", then two questions come up.

Re: [Therion] Extended profile problems

2019-09-06 Thread Martin Sluka via Therion
Hi Bill, it looks you have not defined „extend“ of centerline in your centerline data. Because extend right is default Therion will extend your stations form OC5a to the right, but it has to close the loop and there should be the problem. Your scrap extended Profile-OC5a-G10 includes stations

Re: [Therion] Extended profile problems

2019-09-06 Thread Philippe Vernant
Hi Bill, Not sure to understand what you are trying to do. Are you trying to make the full extended profile of the cave ? In which .th2 is your profile drawing ? Phil > On 6 Sep 2019, at 16:09, Bill Gee wrote: > > Hi Martin - > > This is a commercial cave - there are no secrets! The attach

Re: [Therion] Extended profile problems

2019-09-06 Thread Bill Gee
Hi Martin - This is a commercial cave - there are no secrets! The attached ZIP file has the thconfig, .th, .th2 and centerline data files for the whole project. -- Bill Gee On Friday, September 6, 2019 8:50:38 AM CDT Martin Sluka via Therion wrote: > Bill, > > may you publish all your dat

Re: [Therion] Extended profile problems

2019-09-06 Thread Martin Sluka via Therion
Bill, may you publish all your data? Or send it privately? Martin > 6. 9. 2019 v 15:47, Bill Gee : > > Hello everyone - > > I have not been putting elevation profiles on my maps for several years > because it is such a pain to do in Therion. The time has come where I need > to start adding

[Therion] Extended profile problems

2019-09-06 Thread Bill Gee
Hello everyone - I have not been putting elevation profiles on my maps for several years because it is such a pain to do in Therion. The time has come where I need to start adding them to several maps in progress. In the past I have defined the profile scraps as type "elevation" and given t

Re: [Therion] Detecting errors

2019-09-06 Thread Martin Sluka via Therion
You are the wizard, but for as normal people the physical laws are valid. ;) Martin Odesláno z iPhonu 6. 9. 2019 v 10:39, Pavel Herich : > Martin, > I´ve never used this back extention, but before every "topo day" I use to > calibrate DistoX, which brings me errors under 0,5 % permanetly, very

Re: [Therion] Detecting errors

2019-09-06 Thread Pavel Herich
Martin, I´ve never used this back extention, but before every "topo day" I use to calibrate DistoX, which brings me errors under 0,5 % permanetly, very rarely between 0,5 - 1 %. Pavel Dňa 2019-09-06 10:00 Martin Sluka via Therion napísal(a): 5. 9. 2019 v 13:10, Max D : So I know that if the

Re: [Therion] Detecting errors

2019-09-06 Thread Markus Boldt
Hi Martin, in Ebensee I have asked you, if this part is buyable. Is it? And when where. Best regards Markus Von: Therion [mailto:therion-boun...@speleo.sk] Im Auftrag von Martin Sluka via Therion Gesendet: Freitag, 6. September 2019 10:00 An: List for Therion users Cc: Martin Sluka Betreff: