Marshall:

A 30ma neon transformer I assume will self limit somewhere near 30ma right? Well
if that is so then current can vary between 0-30ma. That to me is current
limiting, not current regulating. Maybe it doesn't matter as the "cone of water"
might act as a current regulator of sorts. I think I will build both types to 
play
with.

Dennis Lipter

Marshall Dudley wrote:

> Neon sign transformers are self limiting.
>
> Marshall
>
> Dennis Lipter wrote:
>
> > Trem:
> >
> > I like your approach to generating CS using a current regulated (1 ma) power
> > supply. With this approach the only variables are time, and water quality. I
> > wonder how this approach applies to the HVAC method. Is it needed or even
> > possible to implement a 10,000 VAC or DC current limited generator?
> >
> > Dennis Lipter
> >
> > "M. G. Devour" wrote:
> >
> > > Hello all,
> > >
> > > Trem Williams sent me this message so I could review it for
> > > compliance with the non-commercial nature of the list. It's just fine
> > > by me, and I am forwarding it to you all because it is good info.
> > >
> > > Constant current has been discussed and is thought to be among the
> > > best techniques we know about. But it hasn't been discussed a lot
> > > recently and it is good to get another developer's point of view.
> > > Thanks for good citizenship and for sharing your results, Trem.
> > >
> > > Be well,
> > >
> > > Mike D.
> > >
> > > >>>>>>>>>>>>Begin included message
> > >
> > > Hello All,
> > >
> > > I have to jump in and pass on some information we have regarding
> > > voltage, current density, current flow, timing, water temperature,
> > > electrode spacing, electrode immersion depth and electrode
> > > deterioration.
> > >
> > > We use 1/4" wide by 5" long silver electrodes with our colloid
> > > generators. This results in quite a large surface area of silver.
> > > Immersion depth is about 3 inches, typically.  Our generators limit
> > > the current with a regulator to a constant, low current value so as to
> > > get very low current density.  We do not get any bubbling, boiling or
> > > any odd looking effects. Just a slow release of silver into the water.
> > >
> > > Our instructions are to not use saline, do not heat the water, use
> > > steam distilled water and place the electrodes at least two inches
> > > apart.  Nothing critical there.  We suggest running the unit for 4-5
> > > hours in 16 ounces of water to get 15-20 PPM.  As you can see, our
> > > generators take quite some time to make a batch but what is a little
> > > extra time when the results are always the same.
> > >
> > > We are able to get repeatable results every time a batch is made.  All
> > > the variables are taken care of by using the constant current
> > > regulator. Spacing and water temperature are not part of the equation.
> > >  All one has to do is use the same amount of distilled water and run
> > > the generator for the same time to get the same results each time.
> > > It's a no brainer.  The key here is CONSTANT CURRENT.
> > >
> > > As far as I'm concerned, using a constant voltage source is the same
> > > as trying to drive a car with the gas pedal stuck to the floor.  The
> > > speed is going to continue to increase until the engine is turned off.
> > >  The same analogy applies to using constant voltage.  Wire spacing,
> > > size, depth of immersion and water temperature are the  variables and
> > > when the silver starts to build up in the water, the current starts to
> > > run away and increase too rapidly.  That's why it bubbles, makes black
> > > particles, gets brown, etc. And it is almost never repeatable.  There
> > > are too many variables in the process using a constant voltage source.
> > >
> > > If one wants to do it inexpensively without using electronic circuitry
> > > to make it automatic, try using a rheostat and milliameter in series
> > > with the battery and electrodes.  These are available at Radio Shack
> > > or any electronic parts store.  After the current starts to flow,
> > > adjust the rheostat to maintain current at some low value.  In our
> > > case we adjust the internal regulator so that it maintains a constant
> > > current flow of 1 milliampere.  I would suggest that value for the
> > > do-it-yourselfers if they use electrodes with equivalent surface area
> > > to our electrodes.  If using wire, the surface area will be less and
> > > the current density will be higher so I can't suggest what current to
> > > use.  I would suggest a lower value.
> > >
> > > It is our experience that the electrodes will last upwards of 700-1000
> > > hours if they are reversed every once in a while.   It is also our
> > > experience that there is little or no sludge or fallout using this
> > > technique.  Particle size is small as attested to by consistently
> > > clear colloidal water without any "sparklers" when a laser is shone
> > > through the water.  The color is golden and depth of color is
> > > determined by length of running time.  It is never cloudy; always
> > > clear.  It is never brown, purple, blue or red.  Just light golden,
> > > clear water.
> > >
> > > The upshot is; use more silver surface area and limit the current and
> > > you will get repeatability.  And that's what we're all after isn't it;
> > > a uniform product?
> > >
> > > Good luck to all.
> > >
> > > Trem Williams
> > > www.silvergen.com
> > >
> > > -----Original Message-----
> > > From: Pam Whitmire <[email protected]>
> > > To: [email protected] <[email protected]>
> > > Date: Monday, June 28, 1999 8:15 PM
> > > Subject: CS strength, times, etc.
> > >
> > > >Ok, I'm confused. Someone told me that you don't WANT to see your silver
> > > >wires bubbling and misting. And NOT to use saline. When I used saline, I
> > > >saw lots of mist rising off one of the wires (I'm using a small
> > > >generator with 3 9volt batteries) and the solution stayed sort of misty.
> > > >Tasted just like the gold-colored CS that I had bought from a company.
> > > >When I didn't use saline, I didn't see anything at all happening. Does
> > > >it take a lot of time? One article said DONT boil the water - another
> > > >said DO boil it. Today I heated the water to approx. 125 degrees,
> > > >started the generator and at about 11 minutes I began to see tiny
> > > >bubbles on one rod. Started timer again, and at the end of about 24
> > > >minutes the one rod was black and starting to form some deposits on the
> > > >end (but none were dropping in the water) the other rod was also
> > > >blackish and beginning to mist a bit from the end. I turned it off and
> > > >have left it alone. How do I know it's correct? Do you just assume that
> > > >you got a good solution because you had the water, silver, generator and
> > > >left it for x amount of time? I know I sound like a real dummy, but I
> > > >really want this to work for me. I appreciate all of you who have taken
> > > >time to answer me....feel free to reply to me personally if that is
> > > >best. Thanks in advance,
> > > >Pam
> > >
> > > --
> > > The silver-list is a moderated forum for discussion of colloidal silver.
> > >
> > > To join or quit silver-list or silver-digest send an e-mail message to:
> > > [email protected]  -or-  [email protected]
> > > with the word subscribe or unsubscribe in the SUBJECT line.
> > >
> > > To post, address your message to: [email protected]
> > >
> > > List maintainer: Mike Devour <[email protected]>
> >
> > --
> > The silver-list is a moderated forum for discussion of colloidal silver.
> >
> > To join or quit silver-list or silver-digest send an e-mail message to:
> > [email protected]  -or-  [email protected]
> > with the word subscribe or unsubscribe in the SUBJECT line.
> >
> > To post, address your message to: [email protected]
> >
> > List maintainer: Mike Devour <[email protected]>
>
> --
> The silver-list is a moderated forum for discussion of colloidal silver.
>
> To join or quit silver-list or silver-digest send an e-mail message to:
> [email protected]  -or-  [email protected]
> with the word subscribe or unsubscribe in the SUBJECT line.
>
> To post, address your message to: [email protected]
>
> List maintainer: Mike Devour <[email protected]>


--
The silver-list is a moderated forum for discussion of colloidal silver.

To join or quit silver-list or silver-digest send an e-mail message to: 
[email protected]  -or-  [email protected]
with the word subscribe or unsubscribe in the SUBJECT line.

To post, address your message to: [email protected]

List maintainer: Mike Devour <[email protected]>