In a message dated 6/12/01 9:50:33 AM EST, [email protected] writes:

<< Subj:     Re: CS>Saline Starter Solutions: Do They Deserve Another Look?
 Date:  6/12/01 9:50:33 AM EST
 From:  [email protected] (Ode Coyote)
 Reply-to:  [email protected]
 To:    [email protected]
 
  Oh yea
  It seems to match all observation that all the silver comes off the
 electrode as ions and forms particles later, mostly at some boundary layer
 that stirring tends to disrupt.
  Most CS will tend to lose some conductivity in a few hours and a light TE
 usually becomes somewhat more pronounced with time as well..indicating that
 non conductive particles continue to form from conductive ionic content
 after the electricity is shut off.  >>

Ken: Another interpretation is that the particles were there all the time, 
but flocculated into larger ones later. Wouldn't such a phenomenon account 
for most of your observations? Roger


--