Sounds like it is not just me: http://track.sipfoundry.org/browse/XX-8221
On Fri, Apr 23, 2010 at 10:27 AM, Picher, Michael <mpic...@cmctechgroup.com>wrote: > It can be. You just either have DNS messed up or your gateways > improperly defined. It’s one of those two things. > > > > Mike > > > > *From:* Rhon [mailto:c4rdi...@gmail.com] > *Sent:* Friday, April 23, 2010 8:47 AM > *To:* Picher, Michael; sipx-users@list.sipfoundry.org > > *Subject:* Re: [sipx-users] Directly Call an extension via Site-to-Site > > > > Hi Michael, > > Sorry for that. > > Both sites are connected via IPSEC GRE tunnel. > > To reach the remote site I dial 200 (i changed the default operator = 200), > I will then dial the extension. > I have problem with establishing calls this way. I just prefer to call > directly any extensions without going to the operator or dialing 200. > > This can be accomplished the other way around. > > Thank you again for all your support. \ > > Rhon > > On Fri, Apr 23, 2010 at 8:37 PM, Picher, Michael <mpic...@cmctechgroup.com> > wrote: > > How are you reaching the remote AA? > > > > You really aren’t giving us much to go on. > > > > *From:* sipx-users-boun...@list.sipfoundry.org [mailto: > sipx-users-boun...@list.sipfoundry.org] *On Behalf Of *Rhon > *Sent:* Friday, April 23, 2010 8:36 AM > *To:* Tony Graziano; sipx-users@list.sipfoundry.org > > > *Subject:* Re: [sipx-users] Directly Call an extension via Site-to-Site > > > > Hmn.. that's strange. I already have this options in placed but still can't > call directly to extension without passing AA. > > Thank you for your patience. > > Rhon > > On Fri, Apr 23, 2010 at 6:33 PM, Tony Graziano < > tgrazi...@myitdepartment.net> wrote: > > You dialplan needs to say, example: > > Prefix "3" and "2 digits, thesend the entire number > > On the "300-399" side, and vice versa. > > > On 4/23/10, Rhon <c4rdi...@gmail.com> wrote: > > Hi Tony, > > > > That's exactly what I did. > > > > As said we have site-to-site running already... it's just that people > have > > to call the AA first become connecting to the desired extension. > > > > What I'm looking at is to go directly to the desired extension without > > passing thru AA always. > > > > Rhon > > > > On Fri, Apr 23, 2010 at 6:23 PM, Tony Graziano < > tgrazi...@myitdepartment.net > >> wrote: > > > >> You create a dial plan of type "site to site". You create an unmanaged > >> gateway on each system with the hostname of the other system. You assign > >> your dialplan for site to site calls to that gateway. > >> > >> Read the wiki. > >> ============================ > >> Tony Graziano, Manager > >> Telephone: 434.984.8430 > >> Fax: 434.984.8431 > >> > >> Email: tgrazi...@myitdepartment.net > >> > >> LAN/Telephony/Security and Control Systems Helpdesk: > >> Telephone: 434.984.8426 > >> Fax: 434.984.8427 > >> > >> Helpdesk Contract Customers: > >> http://www.myitdepartment.net/gethelp/ > >> > >> ----- Original Message ----- > >> From: Rhon <c4rdi...@gmail.com> > >> To: Tony Graziano <tgrazi...@myitdepartment.net>; > >> sipx-users@list.sipfoundry.org <sipx-users@list.sipfoundry.org> > >> Sent: Fri Apr 23 01:06:45 2010 > >> Subject: Re: [sipx-users] Directly Call an extension via Site-to-Site > >> > >> Hi Tony, > >> > >> Thank you for you fast reply. Site-to-Site is already running on both > >> ends. > >> Only that you cannot call an extension without passing the IVR. > >> My intention is to contact an extension directly; without passing the > AA. > >> > >> Rhon > >> > >> On Fri, Apr 23, 2010 at 11:59 AM, Tony Graziano < > >> tgrazi...@myitdepartment.net> wrote: > >> > >> > The wiki shows you how to configure a site to site dial plan. > >> > > >> > You can also program speedials with the sip uri directly into your > phone > >> > (I.e., polycom supports it). > >> > > >> > Dial 2 and 2 digits, send entire number to gateway (other sipx server) > >> and > >> > vice versa. > >> > ============================ > >> > Tony Graziano, Manager > >> > Telephone: 434.984.8430 > >> > Fax: 434.984.8431 > >> > > >> > Email: tgrazi...@myitdepartment.net > >> > > >> > LAN/Telephony/Security and Control Systems Helpdesk: > >> > Telephone: 434.984.8426 > >> > Fax: 434.984.8427 > >> > > >> > Helpdesk Contract Customers: > >> > http://www.myitdepartment.net/gethelp/ > >> > > >> > ----- Original Message ----- > >> > From: sipx-users-boun...@list.sipfoundry.org > >> > <sipx-users-boun...@list.sipfoundry.org> > >> > To: sipx-users@list.sipfoundry.org <sipx-users@list.sipfoundry.org> > >> > Sent: Thu Apr 22 23:39:55 2010 > >> > Subject: [sipx-users] Directly Call an extension via Site-to-Site > >> > > >> > Hi, > >> > > >> > Is there a way I can configure a user to dial an extension directly > from > >> > our > >> > remote office? > >> > > >> > Here's our ext. > >> > > >> > HQ = 200 - 299 > >> > RO = 300 - 399 > >> > > >> > Say user 210 want to directly dial the extension 311 how can I > >> > accomplish > >> > this? > >> > > >> > I was able to use a Phantom User to direct a PSTN call to a live > >> > operator > >> > and was successful. Just don't know how to start with this scenario. > >> > > >> > Hope you can help me. > >> > > >> > Thanks in advance. > >> > > >> > Rhon > >> > > >> > > > > -- > Sent from my mobile device > > > ====================== > Tony Graziano, Manager > Telephone: 434.984.8430 > Fax: 434.984.8431 > > Email: tgrazi...@myitdepartment.net > > LAN/Telephony/Security and Control Systems Helpdesk: > Telephone: 434.984.8426 > Fax: 434.984.8427 > > Helpdesk Contract Customers: > http://www.myitdepartment.net/gethelp/ > > Why do mathematicians always confuse Halloween and Christmas? > Because 31 Oct = 25 Dec. > > > > > > _______________________________________________ > sipx-users mailing list sipx-users@list.sipfoundry.org > List Archive: http://list.sipfoundry.org/archive/sipx-users > Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users > sipXecs IP PBX -- http://www.sipfoundry.org/ > -- ====================== Tony Graziano, Manager Telephone: 434.984.8430 Fax: 434.984.8431 Email: tgrazi...@myitdepartment.net LAN/Telephony/Security and Control Systems Helpdesk: Telephone: 434.984.8426 Fax: 434.984.8427 Helpdesk Contract Customers: http://www.myitdepartment.net/gethelp/ Why do mathematicians always confuse Halloween and Christmas? Because 31 Oct = 25 Dec.
_______________________________________________ sipx-users mailing list sipx-users@list.sipfoundry.org List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/