I dont think so. Not unless they restart Sofia (FS). You can reload the dialplans via socket events "on the fly" in FS, and I don;t think we take advantage of that. So I was just supposing maybe we think or discuss that.
On Wed, Nov 10, 2010 at 1:16 PM, Michael Picher <mpic...@gmail.com> wrote: > If this could be done this way it might be more desirable. > > My only concern would if somebody makes a conf bridge change and they > reload do they then dump the ACD? > > Mike > > > On Wed, Nov 10, 2010 at 1:11 PM, Tony Graziano < > tgrazi...@myitdepartment.net> wrote: > >> I dont know if this helps or not, but here is what was discussed. >> >> [13:05] <@cypromis> actualy we would have to just send a reloadxml >> [13:05] <georgen> I think is about reloadxml >> [13:05] <@cypromis> over event socket >> [13:05] <georgen> >> http://wiki.freeswitch.org/wiki/FreeSwitch_FAQ#Q:_Does_reloadxml_reload_all_XML_files.3F >> [13:05] <georgen> and does not affect conferences, but what about dial >> plans? >> [13:05] <@cypromis> it reloads dial plans >> [13:05] <@cypromis> and all other xml files >> [13:06] <@cypromis> they just do not get activated in all modules >> [13:06] <@cypromis> so to get sofia to reread its configs you would have >> to restart sofia >> >> >> So further discussion might be needed. It might have the desired affect to >> edit and activate dial plans with openacd without breaking a transaction >> though. >> >> On Wed, Nov 10, 2010 at 1:07 PM, Tony Graziano < >> tgrazi...@myitdepartment.net> wrote: >> >>> There was a discussion between myself and anoth dev (Michal Bielicki) who >>> acknoweldged there was a way to reload FS configs without interfering with >>> an in progress transaction. >>> >>> We will try to re-hash that conversation and make it available here (in a >>> nutshell), so this won't really be as much of a nuisance as it currently is >>> (I hope). >>> >>> Tony >>> >>> >>> On Wed, Nov 10, 2010 at 12:31 PM, Todd Hodgen <thod...@frontier.com>wrote: >>> >>>> +1 >>>> >>>> -----Original Message----- >>>> From: sipx-users-boun...@list.sipfoundry.org >>>> [mailto:sipx-users-boun...@list.sipfoundry.org] On Behalf Of Douglas >>>> Hubler >>>> Sent: Wednesday, November 10, 2010 9:24 AM >>>> To: Discussion list for users of sipXecs software >>>> Subject: Re: [sipx-users] when to reload Freeswitch dial plans >>>> >>>> On Wed, Nov 10, 2010 at 10:16 AM, George Niculae <geo...@ezuce.com> >>>> wrote: >>>> > Hi All, >>>> > >>>> > I am working on OpenACD integration (it use Freeswitch dial plans) and >>>> > one requirement is to replicate Freeswitch dial plan on admin action >>>> > only - say admin configures several extensions and wants this to take >>>> > effect only when they all are configured. In order to do this I am >>>> > going to mark Freeswitch service with a reload needed flag and send >>>> > reloadxml command only on a specific action (same way as restarting >>>> > marked services today from services page). >>>> > The issue here is that at this moment conferences are using Freeswitch >>>> > dial plans as well and any change on conferences automatically reloads >>>> > dial plans - this will make also OpenACDs extensions to be taken into >>>> > account. I discussed this with Douglas and agreed for changing >>>> > conference to use same mechanism / workflow: conference changes will >>>> > need a reload action on service page in order to be taken into >>>> > account. >>>> > >>>> > Please let me know what do you think about introducing this new step >>>> > for configuring conferences. >>>> >>>> FYI: This is a very fundamental topic, admins please vote because I >>>> tried to speak on your behalf. >>>> >>>> Quick summary: As an admin, you want to be in control when changes go >>>> live. Even when some portions of the system could make configuration >>>> changes in the background and have a fairly good chance of not >>>> disrupting service. Keywords: *fairly good chance*. If you change >>>> conference settings to a conference already in progress, it may not >>>> always be well defined what freeswitch does for example. NOTE: There >>>> may be special cases however, simple settings like changing a pin or >>>> turning on/off recording are known to be safe and would go live as you >>>> change them. >>>> >>>> What we're proposing is adding to the "Some services need to be >>>> restarted or reloaded" notice and page, a new "Status" that let's you >>>> know the which services would be reloaded and should not experience an >>>> interruption to the service. We would propose we follow this >>>> paradigm when we support reloading of dial plans in proxy/registrar. >>>> How it works today is way too slick IMHO. It waits for a window of 7 >>>> seconds of no new configuration activity has been made, then goes and >>>> deploys the changes. This may work for adding aliases and changes >>>> user's permissions, but not for reloading Freeswitch's configuration. >>>> _______________________________________________ >>>> sipx-users mailing list >>>> sipx-users@list.sipfoundry.org >>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/ >>>> >>>> _______________________________________________ >>>> sipx-users mailing list >>>> sipx-users@list.sipfoundry.org >>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/ >>>> >>> >>> >>> >>> -- >>> ====================== >>> Tony Graziano, Manager >>> Telephone: 434.984.8430 >>> sip: tgrazi...@voice.myitdepartment.net >>> Fax: 434.326.5325 >>> >>> Email: tgrazi...@myitdepartment.net >>> >>> LAN/Telephony/Security and Control Systems Helpdesk: >>> Telephone: 434.984.8426 >>> sip: helpd...@voice.myitdepartment.net >>> >>> Helpdesk Contract Customers: >>> http://support.myitdepartment.net >>> >>> Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4 >>> >>> >> >> >> -- >> ====================== >> Tony Graziano, Manager >> Telephone: 434.984.8430 >> sip: tgrazi...@voice.myitdepartment.net >> Fax: 434.326.5325 >> >> Email: tgrazi...@myitdepartment.net >> >> LAN/Telephony/Security and Control Systems Helpdesk: >> Telephone: 434.984.8426 >> sip: helpd...@voice.myitdepartment.net >> >> Helpdesk Contract Customers: >> http://support.myitdepartment.net >> >> Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4 >> >> >> _______________________________________________ >> sipx-users mailing list >> sipx-users@list.sipfoundry.org >> List Archive: http://list.sipfoundry.org/archive/sipx-users/ >> > > > > -- > There are 10 kinds of people in this world, those who understand binary and > those who don't. > > mpic...@gmail.com > blog: http://www.sipxecs.info > call: sip:mpic...@sipxecs.info <sip%3ampic...@sipxecs.info> > > _______________________________________________ > sipx-users mailing list > sipx-users@list.sipfoundry.org > List Archive: http://list.sipfoundry.org/archive/sipx-users/ > -- ====================== Tony Graziano, Manager Telephone: 434.984.8430 sip: tgrazi...@voice.myitdepartment.net Fax: 434.326.5325 Email: tgrazi...@myitdepartment.net LAN/Telephony/Security and Control Systems Helpdesk: Telephone: 434.984.8426 sip: helpd...@voice.myitdepartment.net Helpdesk Contract Customers: http://support.myitdepartment.net Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4
_______________________________________________ sipx-users mailing list sipx-users@list.sipfoundry.org List Archive: http://list.sipfoundry.org/archive/sipx-users/