[EMAIL PROTECTED] wrote:
>
> The 3c509 does have a batch file pnpdsbl.bat or something similar on the
> 3com etherdisk to disable P7P.
>
> Also, I have major problems getting more than 1 netcard working. In the end
> I found a simple procedure to follow which hasn't failled yet. Install both
> cards as modules, modify modules.conf if needed to specifiy Irq's e.t.c.,
> use Yast to intigrate new netcard into lilo e.t.c. That's it....
>
> Regards,
>
> Tony Melia MCP
> Server Support Group
>
> * +353 1 2044208
> * [EMAIL PROTECTED]
> <<...>>
Me, too.
I've found the only way I can get 2 NICs to work together is
to
use two identical NICs, make sure they are not Plug'n'Pray,
and specify the io and irq explicitly. I've spent hours
trying
to get dissimilar NICs working, and in the end, it's easier,
and far less work, to get two LinkSys NE2000 clones.
Of course, I have read of other people getting 2 different
NICs working, but as you can see, it's a challenge.
George
-
To get out of this list, please send email to [EMAIL PROTECTED] with
this text in its body: unsubscribe suse-linux-e
Check out the SuSE-FAQ at http://www.suse.com/Support/Doku/FAQ/ and the
archiv at http://www.suse.com/Mailinglists/suse-linux-e/index.html