On 12/19/2012 9:19 AM, Entwistle, Bruce wrote:
We installed our APs in the hallways, and found that the APs were seeing such a
strong signal from each other that the Cisco controller would power down the
signal strength for the APs. This was causing a impact on coverage in the
rooms along the hallway.
Cisco's docs say not to use transmission power control in a corridor
style deployment. It's a footnote found in the bottom of a locked
filing cabinet stuck in a disused lavatory with a sign on the door
saying "Beware of The Leopard."
I had to turn TPC off on the APs in the corridor style res halls to get
any sort of reasonable service out of the APs.
-Rick
--
Rick Coloccia, Jr.
Network Manager
State University of NY College at Geneseo
1 College Circle, 119 South Hall
Geneseo, NY 14454
V: 585-245-5577
F: 585-245-5579
**********