the WISPA offender registry...

On 9/1/21 11:53 AM, Chuck McCown via AF wrote:
Might get me on some kind of offender registry.
*From:* Adam Moffett
*Sent:* Wednesday, September 1, 2021 12:19 PM
*To:* af@af.afmug.com
*Subject:* Re: [AFMUG] resistivity of cat5

+1
Use SS or blow ports up during thunderstorms.  Those are the only two options.

Chuck should open a trenchcoat to reveal an assortment of surge protectors inside.

On 9/1/2021 2:15 PM, Chuck McCown via AF wrote:
When he does this, just for shits connect the PSU at the beginning and bridge all the middle stuff and just see if it works.  I will be it will be just fine. However I am certain he needs a ton of surge protectors at each end of all ethernet runs.... just sayin’
*From:* Steve Jones
*Sent:* Wednesday, September 1, 2021 11:26 AM
*To:* AnimalFarm Microwave Users Group
*Subject:* Re: [AFMUG] resistivity of cat5
thats what i suggested trying first, customer wanted the extender, irritating he finally has caved now and will be putting a network rack in the midpoint and is going to place a managed switch there instead of all this other unsupportable cobbling. Sometimes we get a win.
On Wed, Sep 1, 2021 at 11:55 AM Adam Moffett <dmmoff...@gmail.com> wrote:

    Maybe a dumb question, but has it already been tried without the
    extender?

    400ft is beyond 100m, but not by all that much.  It might just
    work without any faffing around.

    On 9/1/2021 11:16 AM, Steve Jones wrote:
    I have a customer fixed on using
    https://i.mt.lv/cdn/product_files/GPeRqg_190928.pdf to extend his
    epmp f300 radio run to 400+ feet.
    if im calculating this right there will be about a 10v drop on
    the 24guage cat5, taking the 30v down to 20. If it does manage to
    keep the radio powered i see it burning out the poe circuit.
    hes fighting me on putting the cambium PSU at the midspan point
    and using his own POE to power the extender.
    Ive been overruled about telling the customer no, so its
    happening, but I want to make sure my math is correct
    using
    https://www.rapidtables.com/calc/wire/voltage-drop-calculator.html
    24guage, 30v, .5 amp, 400 feet shows 10v drop. but im not sure
    about the resistivity field
    this is a guy who runs constant latency monitoring and initiates
    tickets on every blip, so i see this radio move just becoming a
    nightmare with this midspan extender in play

-- AF mailing list
    AF@af.afmug.com
    http://af.afmug.com/mailman/listinfo/af_af.afmug.com

------------------------------------------------------------------------
--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

------------------------------------------------------------------------
--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com


--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to