Wasn't there something about multiple streams mentioned at one point?

___________________________
Tyler Treat
___________________________


On Jul 21, 2015, at 10:57 PM, Josh Luthman 
<j...@imaginenetworksllc.com<mailto:j...@imaginenetworksllc.com>> wrote:

If the Mikrotiks at the customer site are doing 40x10 but the customer devices 
behind the MT it doesn't really make sense to look at the epmp for your problem.

It could be the Mikrotik's CPU, port, wireless or the customer device.


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Tue, Jul 21, 2015 at 11:54 PM, Nate Burke 
<n...@blastcomm.com<mailto:n...@blastcomm.com>> wrote:
I have deployed quite a bit of epmp, but most people are at my base package, 
4x1 (using the radio qos to limit bw on different tiers). Of the handful of 
people that are on larger plans, 20x5 or 40x10, 2 of them, on different towers 
are complaining that they struggle to get over 10mb on a speed test. The radio 
rf link test performs at the assigned qos level, and I sent one of them a 
mikrotik to go between the poe and his router (qos 40x10), and udp/tcp tests to 
that are coming back as expected. However, I can be watching the router, and 
his interface plugged directly into a laptop only runs like 10x2 during a 
speedtest. Do both of these customers have something wonky with their laptops, 
or is there a setting in epmp I'm overlooking? Most of our epmp deployment has 
been FSK upgrades, so I haven't had much actual laptop time myself behind an 
epmp sm, as we just go on the roof and change radios.

Nate

Reply via email to