What are your light levels ? 
SM or MM ? 

Faisal Imtiaz 
Snappy Internet & Telecom 
7266 SW 48 Street 
Miami, FL 33155 
Tel: 305 663 5518 x 232 

Help-desk: (305)663-5518 Option 2 or Email: supp...@snappytelecom.net 

> From: "Chris Wright" <ch...@velociter.net>
> To: af@afmug.com
> Sent: Thursday, October 20, 2016 3:30:03 PM
> Subject: Re: [AFMUG] CRS with sfp lockup

> I’ve seen that same issue as you describe it between CCR1036/CCR1016/CCR1009 
> and
> Netonix switches. Tik says fiber is up at 1Gbps but no rx traffic. Netonix
> detects the cable is plugged in but can’t get any traffic through. Toggling 
> SFP
> to inactive/active usually fixes. Used Fiberstore Generic, Mikrotik, and HP
> SFPs in the Mikrotik – no improvements one over the other. Netonix seems to
> prefer HP SFPs.

> Doing things like turning flow control on/off or changing speed negotiation
> settings on the Mikrotik can induce this problem * sometimes * - depends on
> what mood it’s in. No rhyme or reason when it fails at other times – toggling
> usually fixes it though.

> Chris Wright

> Network Administrator

> From: Af [mailto:af-boun...@afmug.com] On Behalf Of Adam Moffett
> Sent: Thursday, October 20, 2016 12:19 PM
> To: af@afmug.com
> Subject: Re: [AFMUG] CRS with sfp lockup

> I'm not saying this is the same problem....but I have a situation where a 
> Trango
> Apex Lynx loses link to a CCR 1036. The SFP interface on the router says
> there's link, but the SFP interface on the Trango says there isn't. The 
> problem
> (in my case) occurs any time the Trango loses power. I can restore service by
> rebooting the CCR, unplugging and reconnecting the fiber cable, or disabling
> and re-enabling the SFP interface. In this case I didn't have a good picture 
> of
> what was happening at first because when it was happening I didn't have remote
> access to see the condition of everything.

> The Apex Lynx has the JDSU SFP module sold by Trango. I've duplicated the
> problem with 4 different SFP's in the CCR (Mikrotik brand, Maxxwave, JDSU, and
> Finisar), but I haven't tried changing the SFP in the Trango. I don't know how
> common this issue is....it only became apparent after a UPS failed.

> ------ Original Message ------

> From: "TJ Trout" < t...@voltbb.com >

> To: af@afmug.com

> Sent: 10/20/2016 2:30:29 PM

> Subject: [AFMUG] CRS with sfp lockup

>> I have a mikrotik CRS210 with a non-mikrotik sfp which locked up last night, 
>> Not
>> sure if it was the CRS or the sfp...

>> Anyone encountered this and have a solution?

Reply via email to