Oh you have the fancy cable. And indoors there are shielded patch cables etc? I agree that the SSes would be suspected. Also note that if you are using DC over a dedicated non-ethernet line and are using the SAF DC surge protector it is possible to miswire it, I had seen someone do that.
On Wed, Jul 19, 2017 at 2:49 PM, Steve Jones <[email protected]> wrote: > BBDGE > its got the transtector surge suppressor, I'm suspecting that, this is the > only lik with it and both radios are doing it > > On Wed, Jul 19, 2017 at 2:44 PM, Colin Stanners <[email protected]> > wrote: > >> Do you have shielded cable the whole way end to end? SAFs seem to be >> quite sensitive to that. >> >> On Jul 19, 2017 11:20 AM, "Steve Jones" <[email protected]> >> wrote: >> >>> So ive been dealing with the SAFs and the mikrotiks being uppity with >>> one another. >>> SAF has a gigabit port, but it only offers the option to lock it to 100, >>> not gigabit. >>> so I have the mikrotiks set, just not the otherside, the port still >>> flaps on both radios >>> >>> what was happening is everytime it flaps, the interface dropped in ospf >>> and went neighbor down, rerouting traffic then coming back up >>> >>> what I did was made a bridge, added that port to it, and put the ospf ip >>> on the bridge itself, this allows the port to flap without the ospf >>> interface going down until we work throught the issue with SAF >>> >>> I'm wondering if this is causing some other harm having it on the >>> bridge, rather than the physical port >>> >> >