Oh you have the fancy cable. And indoors there are shielded patch cables
etc?  I agree that the SSes would be suspected. Also note that if you are
using DC over a dedicated non-ethernet line and are using the SAF DC surge
protector it is possible to miswire it, I had seen someone do that.

On Wed, Jul 19, 2017 at 2:49 PM, Steve Jones <[email protected]>
wrote:

> BBDGE
> its got the transtector surge suppressor, I'm suspecting that, this is the
> only lik with it and both radios are doing it
>
> On Wed, Jul 19, 2017 at 2:44 PM, Colin Stanners <[email protected]>
> wrote:
>
>> Do you have shielded cable the whole way end to end? SAFs seem to be
>> quite sensitive to that.
>>
>> On Jul 19, 2017 11:20 AM, "Steve Jones" <[email protected]>
>> wrote:
>>
>>> So ive been dealing with the SAFs and the mikrotiks being uppity with
>>> one another.
>>> SAF has a gigabit port, but it only offers the option to lock it to 100,
>>> not gigabit.
>>> so I have the mikrotiks set, just not the otherside, the port still
>>> flaps on both radios
>>>
>>> what was happening is everytime it flaps, the interface dropped in ospf
>>> and went neighbor down, rerouting traffic then coming back up
>>>
>>> what I did was made a bridge, added that port to it, and put the ospf ip
>>> on the bridge itself, this allows the port to flap without the ospf
>>> interface going down until we work throught the issue with SAF
>>>
>>> I'm wondering if this is causing some other harm having it on the
>>> bridge, rather than the physical port
>>>
>>
>

Reply via email to