I'm looking at a revised PSU-like device which should be able to handle this.
What is the maximim per-site load you're looking at? On Wed, Jan 31, 2018 at 2:05 PM, SmarterBroadband <li...@sbb.net> wrote: > Hmmm not enough power, the Telrad BTS draw up to 100 watts, some of our > sites have 6 units. > > I suppose we could have two PDU with 3 on each…. > > > > *From:* Af [mailto:af-boun...@afmug.com] *On Behalf Of *Mathew Howard > *Sent:* Wednesday, January 31, 2018 12:23 PM > *To:* af <af@afmug.com> > *Subject:* Re: [AFMUG] Dc plant conversion > > > > Yep, the PacketFlux PDU is perfect for that. We have a couple of Baicells > eNBs running off them. > > > > On Wed, Jan 31, 2018 at 2:03 PM, Josh Baird <joshba...@gmail.com> wrote: > > PacketFlux (PDU) would be able to power cycle DC powered radios. This is > likely what we'll be doing for Baicells eNB's. > > > > On Wed, Jan 31, 2018 at 2:58 PM, SmarterBroadband <li...@sbb.net> wrote: > > I have been looking at ICT. The ICT600-48SBC Power Supply and the > ICT200DF-12IRC distribution panel. This with a Netonix would do > everything. We have sites with Telrad so the distribution panel will allow > them to be power cycled when necessary. > > > > Anyone using ICT? Bit pricy though, looking at $1,600 plus… > > > > Need a solution where we can power cycle DC powered radios. > > > > Adam > > > > *From:* Af [mailto:af-boun...@afmug.com] *On Behalf Of * > can...@believewireless.net > *Sent:* Saturday, January 27, 2018 3:51 AM > *To:* af@afmug.com > *Subject:* Re: [AFMUG] Dc plant conversion > > > > It's a little spendy but about how about 1 $670 option? Alpha Cordex PSU > 24V 400W. > > Remote monitoring, e-mailed alerts, swappable rectifier, DIN mount, etc. > > Add a Netonix switch and you can power just about anything. > > > > On Fri, Jan 26, 2018 at 8:49 PM, Steve Jones <thatoneguyst...@gmail.com> > wrote: > > Any of you folks who know both dc plant and even more know small wisp > budget interested in looking at our gear and power setup and giving > realistic advice that doesnt have a 10 different 500 dollar components > combined with a full time linux guy and a full time coder? > > > > Id love you to do it out of the kindness of your heart, but i do have some > advisory busget. > > > > Im just tired of the apc ups waste and super ghetto runtimes on batteries > coupled with having to accept we are destroying runtimes by letting the > apcs die..... please, somebody, please. Otherwise i have to go to the > facebook groups, and thats like going to a mikrotik or ubnt forum. > > > > > > > -- *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.* Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602 forre...@imach.com | http://www.packetflux.com <http://www.linkedin.com/in/fwchristian> <http://facebook.com/packetflux> <http://twitter.com/@packetflux>